Integrating The Vs120 Processing Unit As A Device In A Profinet Io Network - Siemens SIMATIC VS120 Operating Instructions Manual

Image processing systems vision sensor
Table of Contents

Advertisement

Commissioning
8.4 Establish an Ethernet connection between the processing unit and PG / PC
Step 3: Establish the Ethernet connection
1. Establish an Ethernet connection between your PC and your existing network. Use a
2. Establish an Ethernet connection between the VS120 processing unit and your existing
Next step
Follow the steps described in the section
8.4.1.5

Integrating the VS120 processing unit as a device in a PROFINET IO network

You want to do the following with the VS120 processing unit:
• Connect to the PC / PG over your existing PROFINET IO network
• Integrate the unit as a device in a PROFINET IO network because the IP configuration
Procedure
1. Configure the VS120 processing unit as a PROFINET IO device
2. Make the parameter settings for the IP configuration of the VS120 processing unit in
3. Integrate your PC in the PROFINET IO network
4. Establish an Ethernet connection
Step 1: Configuring the VS120 processing unit as a PROFINET IO device
1. After turning on the VS120 processing unit and after the self-test is completed, go to the
2. Confirm the selected "Ports" menu command with "OK".
3. Change to the "Ethernet" menu and confirm with "OK"
4. Confirm the selected "IP Mode" menu command with "OK".
5. Select "PNIO" and confirm with "OK"
8-10
network cable of the type "Ethernet RJ-45"
network. Use a network cable of the type "Ethernet RJ-45"
will be assigned by the PROFINET IO controller
Notice
The IP configuration of the VS120 processing unit is set in STEP 7. It is not possible to
set the parameters on the VS120 processing unit.
STEP 7.
"Connect" menu and confirm with "OK".
Note
The VS120 processing reboots after the IP mode is changed to "PNIO".
Check whether a proxy server is being used
Operating Instructions, Edition 02/2006, A5E00757507-01
.