Siemens SIMATIC VS120 Operating Instructions Manual page 74

Image processing systems vision sensor
Table of Contents

Advertisement

Commissioning
8.6 Adjust the sensor head using setup support
2. Position an object below the sensor head
3. Set the displayed image to that it is sharp by adjusting the distance between the end of
4. Secure the sensor head and then check the image sharpness again
5. Make sure that the triggering is exact and the content of the image has as much contrast
6. Click the "Apply" button to save the settings.
Result
You have successfully commissioned "SIMATIC VS120 Vision Sensor". You can now train
and process your models for your application. Refer to the section
information.
8-18
the sensor head and the model correctly
as possible
If necessary, correct the settings or use the automatic shutter mode. You can set the
following parameters:
– Exposure settings
– Trigger settings
– Precision
– Distortion
Notice
If Shutter is set to Auto, the model must remain fully in the image for at least 100 ms.
Note
If you have too many errors, clean the lens and diffuser with a lint-free cloth.
Operation
Vision Sensor SIMATIC VS120
Operating Instructions, Edition 02/2006, A5E00757507-01
for more