Technical data
12.1 General technical specifications
Electromagnetic compatibility
Sine-shaped interference
RF interference
(electromagnetic fields)
Conforming to IEC 61000-4-3
Conforming to IEC 61000-4-3
RF interference on cable/cable
shields
Conforming to IEC 61000-4-6
Emitted interference
Limit class
Transport and Storage of Modules
With regard to transportation and storage conditions, the SIMATIC VS120 surpasses the
requirements specified in IEC 61131-2. The following conditions apply to modules that are
transported and stored in the original packaging.
The climatic conditions correspond to IEC 60721-3-3, Class 3K7 for storage and IEC 60721-3-2,
Class 2K4 for transport.
The mechanical conditions correspond to IEC 60721-3-2, Class 2M2.
Conditions
Free fall
Temperature
Atmospheric pressure
Relative humidity (at +25 °C)
Sine-shaped oscillations complying with
IEC 60068-2-6
Shock complying with IEC 60068-2-29
12-2
Test values
10 V/m at 80 % amplitude
modulation of 1 kHz in the range
from 80 to 1000 MHz
10 V/m at 50% pulse modulation at
900 MHz
Test values
Test voltage 10 V at 80% amplitude
modulation of 1 kHz in the range
from 9 kHz to 80 MHz
Emitted interference of electromagnetic fields in accordance
with EN 55011: Limit class A, group 1;
Emitted interference via the AC input power supply in
accordance with EN 55011: Limit class A, group 1;
Emitted interference and illumination are within the limit value
to comply with EN 55022: Class B.
Permitted range
≤ 1 m (up to 10 kg)
-30 to +70° C
1080 to 660 hPa, corresponds to a height of 1000
to 3500 m
5 to 95%, no condensation
5 - 9 Hz: 3.5 mm
9 - 500 Hz: 9.8 m/s
250 m/s
Operating Instructions, Edition 02/2006, A5E00757507-01
Corr. to severity
Corr. to severity
2
, 6 ms, 1000 shocks
2
Vision Sensor SIMATIC VS120
3
3
3