Vision Sensor SIMATIC VS120
Operating Instructions, Edition 02/2006, A5E00757507-01
Message
Description
Archive
In the self-test, the system waits for the
Esc:Skip
TCP/IP connection to the archiving
software to be established.
TCP/RS232
In the self-test no connection to the
Esc: Skip
configured Ethernet RS-232 converter or.
PC/PG with TCP server can be
established (yet).
PROFIBUS
During the self-test, it is still not possible
Esc:Skip
to start communication over PROFIBUS
DP.
PROFINET
During the self-test, it is still not possible
Esc:Skip
to start communication over PROFINET.
Factory
The defaults for all parameters are used,
Settings
no models have been trained. After the
used.
self-test, the processing unit changes
immediately to the Adjust mode.
This will
IP mode is changed to PNIO or it is in
cause a
PNIO and should obtain a different value.
restart.
The change comes into effect only after a
restart of the processing unit. Confirmation
with "OK" leads to a restart. If you press
"ESC", the change is not applied and no
restart occurs.
This will
If you change the current parameter, the
reset
configured trigger delay source is reset to
DelaySrc
"manual".
Alarm, error and system messages
11.2 Error messages and error handling
Remedies
If the message does not disappear
automatically after a few seconds,
check the connection to the
archiving software.
With ESC, you can skip connection
establishment (or it continues in
the background).
If the message does not disappear
automatically after a few seconds,
check the connection to the
Ethernet RS-232 server or PC/PG
with TCP server.
With ESC, you can skip connection
establishment (or it continues in
the background).
If the message does not disappear
automatically after a few seconds,
check the connection to the DP
master.
With ESC, you can skip connection
establishment (or it continues in
the background).
This message has its origins in the
changeover of the IP address
during reconfiguration. The
message exists until the
changeover procedure has ended.
If the message does not disappear
automatically after a few seconds,
check the connection to the IO
controller.
With ESC, you can skip connection
establishment (or it continues in
the background).