GLP VOLKS LICHT SPOT Instruction Manual page 17

Table of Contents

Advertisement

Channel
Function
Gobo 7
Gobo 8
Gobo 9
Gobo 10
Gobo 11
Gobo wheel rotation CCW
Gobo wheel rotation CW
Gobo wheel rotation Stop
17) Focus
Continues Focus
18) Prism
Prism swing out
Prism position
Prism rotation stop
Prism rotation
Prism by audio
Prism by audio
19) Iris
Iris
20) Special
RESET
Goboshake – Gobo 2
Goboshake – Gobo 1
Gobo – short cut off
1)
Color
The predefined colors can be used as start colors for the Rainbow effect. First select a desired start
color, then activate the rainbow effect. All
execute the rainbow effect synchronously. Different
colors but will still execute the rainbow effect synchronously. If you choose a color different from the
1)
ones marked with
in the tables above the rainbow start-color will be red.
2)
Rainbow-effect Stop
This will pause this function. After resuming the rainbow-effect will be continued with the current color.
3)
The Rainbow-effect
This will run synchronously only if it is started from one of the predefined colors (see also
4)
ATTENTION Shutter:
Please note that shutter frequencies over 10 Hz are prohibited in some countries. Especially
frequencies in the range of 5 - 12 Hz can possibly cause epileptic seizures
irritation with a latency period of min. 70 ms. Please also refer to the relevant legislation of each
country (For Germany for example: BGI 810-4 (Anhang 2) "Sicherheit bei Produktionen und
Veranstaltungen - Scheinwerfer").
Random Shutter Timing:
Function
Random Pulse Effect
Dimming in then shutter close (random)
GLP
German Light Products GmbH
Time and Value
slow
fast
fast
slow
infinity – near
slow
fast
open - close
keep for 3 sec.
slow
fast
slow
fast
V
O
L
K
S
L
I
C
H
T
S
P
O
V
O
L
K
S
L
I
C
H
T
S
P
O
V
O
L
K
S
L
I
C
V
O
L
K
S
L
I
C
DMX value XX to YY
16..46
47
48..78
79
(Instruction version 1.01) / from software version 1.07
DMX
57..63
64..71
72..79
80..87
88..95
130..193
194..254 C2..FE
255
0 .. 255
0..5
6..127
128..129
130..253
254
255
0 .. 255
250..255 FA..FF
80..143
16..79
8..15
T
T
will then begin from that color and
H
T
S
P
O
T
H
T
S
P
O
T
can have different start
continuous blink
timing
60 sec..30 sec
0.3 sec..0.1 sec
60 sec..30 sec
0.3 sec..0.1 sec
HEX
%
39..3F
23..24.5
40..47
25..27.5
48..4F
28..31
50..57
31.5..34
58..5F
34.5..37
82..C1
51..75.5
76..99
FF
100
0..FF
0..100
00..05
0..2
06..7F
0..50
80..81
50,1
82..FD
51..99
FE
99.5
FF
100
00..FF
0 ..100
98..100
50..8F
31..56
10..4F
6..30
08..0F
3..5
1)
before).
17

Advertisement

Table of Contents
loading

Table of Contents