Fresh air intake

In a well-insulated house, the air used up by the burning process has
to be replaced. This particularly applies to houses with mechanical
ventilation. There are different ways of making sure that an air
exchange takes place. The most important thing is to ensure that
there is a supply of air to the room where the wood stove is located.
The external wall vent must be located as close to the wood stove as
possible, and you must be able to close it when you are not using the
wood stove.
National and local building regulations must be followed with regard
to the connection of fresh-air intake.

Closed combustion system

You should use the closed combustion system for the wood-burning
stove if you live in a newly-built, airtight home. Outside air for com-
bustion is connected through a ventilation pipe via the wall or floor.
It must be possible to shut off the ventilation pipe with a valve, when
the stove is not in use.
• Minimum Ø100 mm ventilation pipe, maximum length: 6 m with
a maximum of one bend
The connecting piece for external combustion air is to be found in
the packaging.
If the external combustion air is connected at the rear, the dis-
mounted plate must be mounted on the hole for external air in the
bottom of the stove.
NOTE: if the stove has a fresh air connexion or closed combustion,
the ventilation pipe must be open, when the stove is in use!
A S S E M B LY
Scan 68
NAVN:
MATERIALE:
DIMENSION:
C:\Working Folder\Designs\Scan 68\90068028.idw
STI:
Scan 68
NAVN:
MATERIALE:
DIMENSION:
C:\Working Folder\Designs\Scan 68\10068900 - Manual.iam
STI:
Scan 68 Pedestal
The external air supply can be connected through the pedestal or the
portal by mounting the delivered connecting piece.
Scan 68 Portal.
Friskluft pedestal
EMNE:
AREAL:
If you want to connect an external air supply from the bottom of the
base, remove the blind flange and mount it at the top of the base.
Then mount the delivered connecting piece under the base as shown
below.
Portal sokkel mont.
EMNE:
N/A
AREAL:
External air supply
through the wall.
External air supply
through the floor.