  • Page 1 1005 1006 UK - ASSEMBLY AND INSTRUCTIONS MANUAL SCAN 1005 1006 ASSEMBLY AND INSTRUCTION MANUAL SCAN 1005 1006...
  • Page 2 1005 1006 CONGRATULATIONS ON YOUR NEW SCAN BUILT-IN STOVE You have purchased a product by one of Europe’s leading manufacturers of wood-bur- ning stoves, and we are sure that you will have years of pleasure from your purchase. To make the best possible use of your stove, it is important that you follow our advice and instructions.
  • Page 3: Table Of Contents

    CONTENTS ¬ ¬ TECHNICAL DATA Installation Dimension sketch Scan 1006 Safety Type plate Technical data and dimensions Product registrationumber Dimension sketch Scan 1005 ¬ ¬ ASSEMBLY Tools needed for mounting of the insert Building into flammable material with fire wall...
  • Page 4: Technical Data

    Any changes made to the product by the dealer, fitter or user could result in the product and safety functions not functioning as intended. The same applies to the fitting of accessories or extra equipment not supplied by Scan A/S. This could also be the case if parts that are necessary for the operation and safety of the stove are dismantled or removed.
  • Page 5: Technical Data And Dimensions

    Galvanised sheet down until only the embers are left before refuelling. Materials Ceramic stone/vermiculite Chamotte Scan 1005-1006 is produced in accordance with type approv- Robax glass al for the product, which also covers the product’s Assembly and Instruction Manual. Surface treatment Senotherm The Declaration of Performance (DoP) is available from www.
  • Page 6: Dimension Sketch Scan 1005

    DIMENSION SKETCH SCAN 1005 Top outlet Rear outlet Centre external air supply, rear side Centre of external air supply, bottom All measures are in mm...
  • Page 7: Dimension Sketch Scan 1006

    DIMENSION SKETCH SCAN 1006 Top outlet Rear outlet Centre external air supply, rear side Centre of external air supply, bottom All measures are in mm Scan 1006 91006001_stregtegning NAVN: EMNE: TG.NR:...
  • Page 8: Type Plate

    TYPE PLATE All Scan built-in stoves are fitted with a type plate that specifies the approval standards and the distance to flammable materials. The type plate (Vermiculite) is located on top of the stove. The type plate (Ceramic stone) is in the box with the ceramic stones and must be stuck on top of the existing type plate.
  • Page 9: Product Registrationumber

    PRODUCT REGISTRATIONUMBER All Scan built-in stoves are provided with a product registration number. Please make a note of this number at the rear page of this manual; you will always need to quote it when contacting your dealer or Scan A/S.
  • Page 10: Assembly

    Convection adaptors Ø149 mm (see page 21) ¬ Convection grates (See page 27) DISPOSAL OF PACKAGING Your Scan built-in stove may come supplied with the following packaging: The wood packaging can be reused and after final use can be incinerated as a CO neutral Wood packaging product or sent for recycling.
  • Page 11: Floor Plate

    EXISTING CHIMNEY AND PRE-FABRICATED ELEMENT CHIMNEY If you intend to connect your stove to an existing chimney, it makes sense to contact an authorised Scan dealer, or a local chim- ney sweep, for advice. These experts will also let you know if your chimney needs renovating.
  • Page 12: Trims And Doors

    SAFETY DISTANCE European, national and local regulations concerning safety distances for wood-burning stoves and flue pipes must be complied with. Pakning på svøb 91001036 EMNE: TG.NR: DATO: 11-05-12 VÆGT: SIGN: AREAL: Krog Iversen & Co A/S DK-5492 Vissenbjerg© Folder\Designs\Scan 1001\91001036.idw...
  • Page 13: Building Into Flammable Material With Fire Wall

    TG.NR: 02-05-12 MATERIALE: VÆGT: DATO: SIGN: Min. 500 cm DIMENSION: AREAL: Krog Iversen & Co A/S Upper DK-5492 Vissenbjerg© C:\Working Folder\Designs\Scan 1001\91001029.idw STI: convection opening (Ceramic stone) (Vermiculite) Min. 350 cm Lower convection opening Distance to furniture from glass Floor Uisoleret røgrør...
  • Page 14 SIGN: VÆGT: AREAL: Krog Iversen & Co A/S DK-5492 Vissenbjerg© ng Folder\Designs\Scan 1005\91005030.idw Floor The distance to fire wall (brick) depends on the use of an insulated flue pipe all the way down to the insert Konstruktion/omramning mod loft Scan 1005...
  • Page 15 When building or fitting into a structure/sur- round that is open at the top, the convection holes can be omitted. However, you should note that no top plate must be placed on the structure Scan 1001 Åben indbygning Scan 1001 91001050 TG.NR: NAVN: EMNE: Floor...
  • Page 16: Operating The Door

    Check that the built-in stove is not damaged before installing it. Scan 1005/1006 is delivered secured to the pallet. It is recommended that you remove the door and take all loose parts out of the combustion chamber before unscrewing the stove from the pallet; this will facilitate the mounting of the insert.
  • Page 17 TG.NR: 91005012 DATO: 23-04-2018 SIGN: MATERIALE: VÆGT: DIMENSION: AREAL: Krog Iversen & Co A/S DK-5492 Vissenbjerg© C:\Working Folder\Designs\Scan 1005\91005012.idw STI: Remove the two screws securing the cassette to the pallet Afmontage røgstuds Scan 1005 EMNE: TG.NR: 91005004 13-03-2018 ALE: VÆGT:...
  • Page 18: Fitting The Flue Connection Piece

    Mount the gasket 3 x 8 mm at the edge of the flange of the connecting piece. Fasten the connecting piece with the flanged nuts Gasket Montage røgstuds Scan 1005 NAVN: EMNE: MATERIALE: VÆGT: DIMENSION: AREAL: 4 x flange nuts M6 C:\Working Folder\Designs\Scan 1005\91005028.idw STI: Montage røgstuds Scan 1001 91001025 NAVN: EMNE: TG.NR: MATERIALE: VÆGT: DATO:...
  • Page 19: Mounting Of External Air Supply

    EMNE: Krog Iversen & Co A/S TG.NR: MATERIALE: VÆGT: DATO: 07-05-2012 SIGN: DK-5492 Vissenbjerg© Working Folder\Designs\Scan 1005\91005009.idw DIMENSION: AREAL: Krog Iversen & Co A/S DK-5492 Vissenbjerg© C:\Working Folder\Designs\Scan 1001\91001032.idw STI: Mount the Ø100 sleeve Ekstern forbrænding bag på svøb an 1001...
  • Page 20 NAVN: EMNE: TG.NR: 91001032 07-05-2012 MATERIALE: VÆGT: DATO: SIGN: DIMENSION: AREAL: Krog Iversen & Co A/S DK-5492 Vissenbjerg© C:\Working Folder\Designs\Scan 1001\91001032.idw STI: Mount the Ø100 sleeve Scan 1001 Frisklufttilførsel bund af ovn 91001032 NAVN: EMNE: TG.NR: 07-05-2012 MATERIALE: VÆGT: DATO:...
  • Page 21: Fitting Without The Convection Connection Pieces

    Krog Iversen & Co A/S DK-5492 Vissenbjerg© FITTING THE CONVECTION CONNECTION PIECES (ACCESSORY) C:\Working Folder\Designs\Scan 1005\91005017.idw STI: Convection connection pieces Ø149 mm To dismount the cover plates for the convection adaptors, use an slotted screwdriver as shown below. Tilt the screwdriver and loosen the cover plates.
  • Page 22: Fitting The Cassette

    EMNE: TG.NR: 02-05-12 DATO: MATERIALE: VÆGT: SIGN DIMENSION: AREAL: Krog Iversen & Co A/ DK-5492 Vissenbjerg C:\Working Folder\Designs\Scan 1001\91001030.idw STI: Isætning cassette Scan 1001 EMNE: TG.NR: 91001014 To ensure that the cassette is level, you can adjust 23-04-12 VÆGT: DATO:...
  • Page 23 NAVN: EMNE: MATERIALE: VÆG DIMENSION: AREAL: C:\Working Folder\Designs\Scan 1001\91001013.idw STI: Mount the rawl plugs, screws and discs. Make sure that the cassette is level before fastening it. In order to fasten the insert, you can use the delivered torx key that you will find...
  • Page 24 DATO MATERIALE: VÆGT: DIMENSION: AREAL: C:\Working Folder\Designs\Scan 1001\91001018.idw STI: Remove the top plate of the cassette The top plate of the cassette can be dismounted, after the cassette has been fastened. This can help facilitating the mounting of the insert...
  • Page 25: Mount The Insert In The Cassette

    91001027 AVN: EMNE: TG.NR: 26-04-2012 MATERIALE: VÆGT: DATO: SIGN: IMENSION: AREAL: Krog Iversen & Co A/S DK-5492 Vissenbjerg© C:\Working Folder\Designs\Scan 1001\91001027.idw Grip holes for pivot pins Styretapper og fanghuller Scan 1001 NAVN: EMNE: TG.NR: 91001017 24-04-12 MATERIALE: VÆGT: DATO: SIGN:...
  • Page 26: Mounting Of The Trim

    DIMENSION: AREAL: Krog Iversen & Co A/S DIMENSION: AREAL: Krog Iversen & Co A/S DK-5492 Vissenbjerg© C:\Working Folder\Designs\Scan 1001\91001031.idw STI: DK-5492 Vissenbjerg© C:\Working Folder\Designs\Scan 1001\91001031.idw STI: Remount the top plate of the cassette and the door MOUNTING OF THE TRIM We recommend that you do not mount the trim, until the insert has been approved by the chimney sweep, as he may demand to see the type plate which is situated on the top plate of the cassette (to dismount the top plate, see page 24).
  • Page 27: Mounting Of Convection Grate

    Indbygningsmål i mur Indbygningsmål i mur Indbygningsmål for konvektionsrist 91001053 EMNE: TG.NR: 1,64 kg 05-09-2017 VÆGT: DATO: SIGN: 279757 mm^2 AREAL: Krog Iversen & Co A/S DK-5492 Vissenbjerg© er\Designs\Scan 1001\91001053.idw...
  • Page 28: Mounting Of Combustion Chamber

    Place the bottom stones with the inclined edge turning MENSION: AREAL: Krog Iversen & Co A/S to the rear and downwards DK-5492 Vissenbjerg© C:\Working Folder\Designs\Scan 1005\91005019.idw Mount the left rear plate Mount the left burn chamber plate Montering af bundsten Scan 1005 9100 Montering af kævlefang...
  • Page 29 VÆGT: MATERIALE: VÆGT: ENSION: AREAL: DIMENSION: AREAL: Krog Iversen & Co A/S Krog Iversen & Co A/S DK-5492 Vissenbjerg© DK-5492 Vissenbjerg© C:\Working Folder\Designs\Scan 1005\91005025.idw C:\Working Folder\Designs\Scan 1005\91005026.idw STI: Montering af nederste røgvenderplade Scan 1005 91005024 NAVN: EMNE: TG.NR: 21-03-2018 MATERIALE: VÆGT:...
  • Page 30: Adjustment Of The Door

    The adjustment screw is placed at the top of the hinge as shown below. Justering af låge Scan 1005 91005032 NAVN: EMNE: TG.NR: 22-05-2018 DATO: SIGN: MATERIALE: VÆGT: DIMENSION: AREAL: Krog Iversen & Co A/S Justering af låge 1005 91005032 EMNE: TG.NR: DK-5492 Vissenbjerg© C:\Working Folder\Designs\Scan 1005\91005032.idw STI: 22-05-2018 VÆGT: DATO: SIGN:...
  • Page 31: Instructions For Use

    Adjustment of air supply, primary and secondary damper CB-technique Primary air 0%-100% 0%-100% Tertiærkasse, luftindikator Scan 1005 91005014 NAVN: EMNE: TG.NR: 19-03-2018 MATERIALE: VÆGT: DATO: SIGN: Primary air Secondary air DIMENSION: AREAL: Krog Iversen & Co A/S DK-5492 Vissenbjerg© C:\Working Folder\Designs\Scan 1005\91005014.idw STI:...
  • Page 32: Instructions For Heating

    LIGHTING We recommend the use of fire lighters, or similar products, which are available from your Scan dealer. Using fire lighters helps light the wood more quickly and keeps the combustion process clean. See our video about correct firing on www.scan.dk or scan the QR-code. Please note that this Scan the QR-code video is only intended as a guide.
  • Page 33: Continuous Operation

    CONTINUOUS OPERATION It is important to obtain as high a temperature as possible in the combustion chamber. This results in best possible use of the stove and fuel, as well as achieving clean combustion. In this way you will avoid build-up of soot on the combustion chamber lining and glass pane.
  • Page 34: The Function Of The Chimney

    THE FUNCTION OF THE CHIMNEY The chimney is the wood-burning stove’s motor; its performance determines how well your stove will work. The draught in the chimney creates negative pressure in the wood-burning stove. The negative pressure draws the smoke out of the stove and takes in air through the combustion air damper to fuel the combustion process.
  • Page 35: Handling Of The Fuel

    HANDLING OF THE FUEL SELECTING WOOD/FUEL You can use any type of wood as fuel. However harder woods, such as beech or ash, are generally better for heating, as they burn more evenly and create less ash. Other woods, such as maple, birch and spruce, are excellent alternatives. PREPARATION The best fuel is obtained where the tree has been felled and the wood sawn and split before May 1st.
  • Page 36: Maintenance

    Clean your wood-burning stove by wiping it down with a dry, lint-free cloth. If the paint finish gets damaged, you can purchase repair paint in spray form from your Scan dealer. As slight differences in colour shade are possible, we recommend you spray a larger area to achieve a natural blend. For best results, apply repair spray when the stove is warm enough for you to just keep your hand on it, but no hotter.
  • Page 37: Cleaning The Glass

    TG.NR: 15-03-2018 MATERIALE: VÆGT: DATO: SIGN: DIMENSION: AREAL: Krog Iversen & Co A/S DK-5492 Vissenbjerg© C:\Working Folder\Designs\Scan 1005\91005011.idw STI: DISPOSAL OF STOVE PARTS Steel/cast iron Send for recycling Glass Dispose of as ceramic waste Brændkammerforing, eksploderet Scan 1005 91005012 NAVN: EMNE: TG.NR:...
  • Page 38 TROUBLESHOOTING SMOKE ESCAPING ¬ Damp wood ¬ Chimney not drawing properly ¬ Chimney is not properly dimensioned for the built-in stove ¬ Check if the smoke gas pipe/chimney are blocked ¬ Is the chimney the right height for its surroundings? ¬...
  • Page 39 You must quote your stove‘s product registration number when you contact us or your authorised Scan dealer with a warranty claim. The warranty covers all parts which in the opinion of Scan A/S require repair or replacement due to manufacturing or construc- tion error The warranty applies to the original purchaser of the product only, and is not transferable (except on prior sale).
  • Page 40 NOTES...
  • Page 44 Product registration number Quote this number at all enquiries Edition: UK 91005500 SCAN A/S Glasvænget 3-9 DK-5492 Vissenbjerg www.scan.dk 29.08.2019...