Congratulations on your new Scan wood-burning stove
You have purchased a product by one of Europe's leading manufacturer's of wood-burning stoves, and we are sure that you will have years of
pleasure with your purchase. To make the best possible use of your stove, it is important that you follow our advice and instructions.
Please read this Assembly- and instructions manual before you start to assemble your stove.
Product registration number
Please indicate the product registration number at any enquiry
S C A N A / S - D K- 5 4 9 2 V I S S E N B J E R G

Advertisement

Table of Contents
loading

Summary of Contents for SCAN 66 Series

  • Page 1 A S S E M B LY- A N D I N ST R U C T I O N S M A N UA L Scan 66 series Congratulations on your new Scan wood-burning stove You have purchased a product by one of Europe’s leading manufacturer’s of wood-burning stoves, and we are sure that you will have years of pleasure with your purchase.
  • Page 2: Table Of Contents

    C O N T E N T S Table of contents Technical data ..........................3 Installation Safety Technical data and dimensions Dimension sketches Type plate Product registration number Assembly ............................10 Additional accessories Loose parts Disposal of packaging Mounting of the base/wall fitting Mounting of the burn chamber Positioning your wood-burning stove Distance to furniture...
  • Page 3: Technical Data

    The same applies to the fitting of accessories or extra equipment Instruction Manual. not supplied by Scan A/S. This could also be the case if parts that are necessary for the operation and safety of the stove are dismantled or When you install any kind of fireplace or stove, you must inform the removed.
  • Page 4 Assembly and Instruction 33 cm Max. wood length Manual. ca. 90-108 kg Weight The Declaration of Performance (DoP) is available from www.scan.dk 144 mm Connecting piece internal diameter 148 mm Connecting piece external diameter Approval type Intermittent fuelling PLEASE NOTE: You get the best use of the stove by using a ”top-down...
  • Page 5 T E C H N I C A L D ATA Dimension sketch Scan 66-1 Wall Front 166**** 171**** Front Centre rear outlet Height to the beginning of the connecting piece at top outlet Fresh air intake at the back of the stove...
  • Page 6 T E C H N I C A L D ATA Dimension sketch Scan 66-2 Pedestal Front Centre rear outlet Height to the beginning of the connecting piece at top outlet Fresh air intake at the back of the stove...
  • Page 7 T E C H N I C A L D ATA Dimension sketch Scan 66-4 Plinth Front Centre rear outlet Height to the beginning of the connecting piece at top outlet Fresh air intake at the back of the stove...
  • Page 8 T E C H N I C A L D ATA Dimension sketch Scan 66-5 S- Curve 168,5 1037...
  • Page 9: Type Plate

    T E C H N I C A L D ATA Type plate Product registration number All Scan wood-burning stoves are fitted with a type plate that speci- All Scan wood-burning stoves are provided with a product registra- fies the approval standards and the distance to flammable materials.
  • Page 10: Assembly

    • Repair lacquer for colored stoves Disposal of packaging Your Scan stove may come supplied with the following packaging: WOOD PACKAGING: The wood packaging can be reused and after final use can be incinerated as a CO2 neutral product or sent for recycling.
  • Page 11 In order to mount the wall fitting to a chimney made of Leca-blocks you need 6 pcs. FBS 8x70/5 US Leca screws. The test report can be required at Scan A/S. Wall mounted room heater fired by solid fuel Minimum distance to combustible materials...
  • Page 12 A S S E M B LY Mount the wall fitting on the wall. Dismount the rear plate by removing the four screws. Place the rear plate on an even surface. It is important that it is level. Mount bushing, screw and nut. Remove the slits –...
  • Page 13 A S S E M B LY Mount the bottom plate on the existing four screws. Let the rails glide down through the hole along the bottom plate. Mount the two adjustment screws. Mount the four screws loosely in the rear plate again, now with the wall fitting in between.
  • Page 14 Approved by Intermittent EN 13240 Teknologisk Institut Klasse 2 ELAB-2081-NS Teknologisk Institut Norway Schweiz Germany Follow assembly- and instructions manual. Use only recommended fuels. Montage- und Bedienungsanleitung beachten. Verwenden Sie nur empfohlene Brennstoffe. 1000 Scan A/S DK 5492 Vissenbjerg 08-2014...
  • Page 15 A S S E M B LY Scan 66-2 External combustion air from the bottom Use the delivered division plate. First cut out the hole, mount the division plate, then the pedestal. Fasten the screws. (see page 26) No external combustion air External combustion air from the rear Mount the pedestal directly on the stove, without the division plate.
  • Page 16 A S S E M B LY Scan 66-4 Fasten the four screws after mounting the base. Prepared for external air at the bottom. Cut out the hole with a pair of cutting nippers.
  • Page 17 A S S E M B LY Scan 66 -5 Loosen the four screws (ca. 4-5 mm) so that it is possible to hook the base on the stove. Mount the S-shaped base on the stove before removing the packing.
  • Page 18 A S S E M B LY 1 Scan 66-stove body 6 Skamol plates 2 pins for baffle plates 1 connecting piece for external combustion air 1 log guard made of glass Opening of the door Push the handle backwards in order to open the door.
  • Page 19 A S S E M B LY 11 19 Please remove protection Mount the rear plate Slide the plate behind the grate Rear plate mounted Fit the left side plate in at the top Slide the plate in place Right side plate mounted Left side plate mounted Mount the right side plate in the same way as the left plate...
  • Page 20 A S S E M B LY Let the plate glide back on the Upper baffle Mount the upper baffle (the upper edge carvings must turn backwards) Push the plate a bit backwards so Lower baffle Push the plate upwards so that it that it rests on the rail in the back rests on the front plate Mount the pins in the side plates...
  • Page 21: Positioning Your Wood-Burning Stove

    30 mm insulation. Wood Storage Scan 66-5 S-Curve is approved for wood storage on condition that the following is respected: The wood must be placed min. 100 mm from the stove and is not to be stapled higher than to the lower edge of the handle.
  • Page 22: Distance To Flammable Materials, Shown With Insulated Flue Pipe

    A S S E M B LY Distance to flammable materials, shown with insulated flue pipe 45° Corner installation Parallel rear wall installation Distance to flammable materials, shown with insulated flue pipe The distances presuppose the use of an insulated flue pipe all the way to the stove. 45°...
  • Page 23: Distance To Firewall

    A S S E M B LY Distance to firewall The indicated distances are valid for insulated as well as un-insulated smoke pipes. Flammable material Firewall...
  • Page 24: Height Adjustment Of Stove

    Your local Scan dealer can advise you on regulations concerning pro- tection of flammable materials in the vicinity of your stove.
  • Page 25: Existing Chimney And Pre-Fabricated Element Chimney

    If you intend to connect your stove to an existing chimney, it makes The connecting piece is placed loosely in the top outlet of the stove. sense to contact an authorised Scan dealer, or a local chimney sweep, The gasket for the connecting piece and the screws for fastening the for advice.
  • Page 26 A S S E M B LY Top outlet Rear outlet Click...
  • Page 27: Fresh Air Intake

    A S S E M B LY Fresh air intake In a well-insulated house the air used for the combustion process External combus- has to be replaced. This particularly applies to houses with mechan- tion air through the ical ventilation. There are different ways of making sure that air is wall exchanged.
  • Page 28 A S S E M B LY / I N S T R U C T I O N S F O R H E AT I N G Dampers left open Fuel overloading Operation with the air controls or appliance dampers open can cause The maximum amount of fuel specified in this manual should not be excess smoke.
  • Page 29: Instruction For Heating

    I N S T R U C T I O N S F O R H E AT I N G CB-technique (Clean Burning) Baffle plates The wood-burning stove is equipped with CB technology. In order to The baffle plates are located in the upper part of the combustion ensure an optimal combustion of released gases under the incinera- chamber.
  • Page 30: Lighting

    Lighting We recommend the use of fire starters, or similar products, which are available from your Scan dealer. Using fire starters helps to light the wood quicker, and keeps the burning process clean. Never use liquid lighting fuels! "Top down"...
  • Page 31: Handling Fuel

    I N S T R U C T I O N S F O R H E AT I N G F Y R I N G S I N S T R U K T I O N 19 31 Using your stove in the spring or autumn Handling fuel In the transition period (spring/autumn), where there is less need...
  • Page 32: Maintenance

    Checking the stove Wood types Compared beech Scan A/S recommends that you check your stove thoroughly after Hornbeam sweeping/cleaning. Check all visible surfaces for cracks. Check that Beech/Oak all joints are tight and that the seals sit correctly. Worn or deformed seals should be replaced.
  • Page 33 M A I N T E N A N C E The glass log guard is easy to remove and can be clea- ned with glass cleaner. Log guard Ash drawer Pull out the ash drawer and empty it.
  • Page 34 M A I N T E N A N C E Service The door does not close It may occur during transport that the locking device moves out if its correct position, so that the door does not close properly. This can Baffle plates easily be adjusted, see below.
  • Page 35: Troubleshooting

    Scan dealer with a warranty claim. • Check if the smoke gas pipe/chimney are blocked The warranty covers all parts which in the opinion of Scan A/S require • Is the chimney the right height for its surroundings? repair or replacement due to manufacturing or construction error •...