FRESH AIR INTAKE

In a well-insulated house the air used for the combustion process has to be replaced. This particularly applies to houses with
mechanical ventilation. There are different ways of making sure that air is exchanged. The most important thing is to ensure
that there is a supply of air to the room where the built-in stove is located. The external wall vent must be located as close to the
stove as possible, and you must be able to close it when you are not using the stove.
National and local building regulations must be followed with regard to connection of a fresh air intake.
The diameter of the connection piece for fresh air is 125 mm. If you want to use a 100 mm connection tube you can mount a
gasket on the outside of the tube before mounting the tube inside the connection piece.

CLOSED COMBUSTION SYSTEM

You should use the closed combustion system for the built-in stove if you live in a newly-built, airtight home. External
combustion air is connected through a ventilation pipe via the wall or floor.
We recommend mounting a valve in the ventilation pipe in order to avoid condensate in the stove and the pipe system, which can
be closed when the oven is not in use. It can also be an advantage to insulate the ventilation pipe.
Minimum Ø 100 mm ventilation pipe, maximum length:
metres with a maximum of one bend. We recommend smooth steel pipes.
6
NOTE: If the stove has a fresh air connexion or closed combustion, the ventilation pipe must be open, when the stove is in use!

FRESH AIR BOX FOR FLOOR

(ACCESSORY)
A fresh air box and connection pipe (Ø 100 mm) are available as accessories.
66
12
Drawing
Friskluftsadapter