Page 1
A S S E M B LY- A N D I N S T R U C T I O N S M A N U A L Scan 1001 Congratulations on your new Scan built-in stove You have purchased a product by one of Europe’s leading manufacturer’s of wood-burning stoves, and we are sure that you will have years of plea- sure with your purchase.
C O N T E N T S Table of contents Technical data ......................3 Scan 1001 versions Installation Safety Technical data and dimensions Dimension sketch1 Product registration number Type plate Assembly ........................6 Operating the door Loose parts Service box...
To ensure best-possible functionality and safety for your installation, we advise you to call a professional fitter. Our Scan Dealer will be able Intermittent fuelling means normal use of a woodstove. In other to recommend a qualified fitter in your area.
T E K N I S K E D ATA Product registration number Type plates All Scan wood-burning stoves are fitted with a type plate, that speci- All wood-burning stoves are provided with a product registration fies the approval standards and the distance to flammable materials.
The door should be banged shut, as on a car. Grip the handle (hold in a horizontal position) and bang the door shut. Service box The service box contains the following: • Fitting for connecting piece (not used for this Scan model) • Seal • Safety fitting (not used for this Scan model) •...
Push the connecting piece in the direction of the arrow and remove it. Scan 1001 is delivered secured to the pallet. It is recommended that you remove the door and take all loose parts out of the combustion chamber before unscrewing the stove from the pallet;...
If you intend to connect your stove to an existing chimney, it makes Convection means that air circulation occurs, so that the heat is sense to contact an authorised Scan dealer, or a local chimney sweep distributed more evenly around the room.
Page 9
A S S E M B LY Data to use when building in the insert, see fig. 1 Minimum Scan 1001 measurements Building height over flammable floor 400 mm Free height over horizontal flue pipe to insulation material 600 mm...
Page 18
Place the bottom stones with the inclined edge turning to the rear The rear burn chamber plates must be mounted so that the holes of and downwards. the plates are placed precisely over the tertiary holes of the insert. Nederste røgvenderplade Scan 1001 NAVN: EMNE: DATO: MATERIALE: VÆGT:...
Lighting We recommend the use of fire starters, or similar products, which are available from your Scan dealer. Using fire starters helps to light the wood quicker, and keeps the burning process clean. Never use liquid lighting fuels!e! "Top down"...
I N S T R U C T I O N S F O R H E AT I N G Handling fuels Why you need a chimney The chimney is the wood-burning stove‘s motor; it‘s performance decides how well your stove will work. The draft in the chimney Selecting Wood/Fuel creates a vacuum in the wood-burning stove.
Even if you follow all of our instructions, a slight film of soot can build up on the glass. You can easily remove this build up by cleaning with a dry cloth and glass cleaner. Your authorised Scan dealer stocks a special glass cleaner for this purpose.
Scan dealer with a warranty claim. • Is the chimney the right height for its surroundings? The warranty covers all parts which in the opinion of Scan A/S require • At rear outlet, check that the flue pipe does not obstruct the...