5.1.10. Anti-crushing Sensitivity
The D5-Evo, D10 and the
D10 Turbo incorporate a
sensitive electronic anti-crushing
technology that activates if a
person or vehicle obstructs your
gate.
The operator will respond
differently to obstructions
depending on the Operating
Standard (e.g. CE, UL325) you
select. The typical response for
an opening gate is to
immediately stop and a closing
gate will stop then immediately
reopen.
Collision force can be set
independently per direction of
travel and can be set from
minimum to maximum in five
incremental steps. A sixth
incremental step will disable
collision sensing entirely and
allow for maximum force – the
motor will run until it stalls at
which point a collision will be
detected.
Step six should only be used if additional safety measures
such as infrared beams and sensitive edges are present
5.1.10.1. Collision Count
A counter monitors the number of collisions the gate experiences
before it fully closes. If the number exceeds the default value of
four, which can be adjusted in the Multiple Collisions Counter, the
controller will shut down. The Status LED (page 20) will flash four
times every second until a valid trigger is received
Please refer to Gate Status Indication (page 20) for more
information on this diagnostic device
Gate closes, hits obstruction,
stops and closes immediately
FIGURE 22
Gate opens,
hits obstruction and stop
page 17
Features
functions
FIGURE 23
and