Network Job Mode; Production Mode; Table 12. Determining The Large Display Contents - Baum 2020 Instruction Manual

1st station folder w/pile feed
Hide thumbs Also See for 2020:
Table of Contents

Advertisement

Exit Make Ready Mode
h
Pressing any of these keys will cause the controller to
change to a new mode.

2.6 Network Job Mode

Pushing this key puts the counter in network job mode
+
+
This mode is only available if a STA-NET adapter is
installed and activated through maintenance mode. In this
mode the small display (2) always shows the word 'Job'.
The large display (1) shows either 'PAuSE' or a job
number which can be read from the network. The suction
length display is disabled.
Select Job Number
+
+
This set of plus and minus keys step the large display
(1) through pause mode and a list of available job numbers.
While in network job mode, the folder is considered to be
paused.
Load Job and Return to Run Mode
When this button is pushed the selected job will be
loaded into the counter and the counter will return to run
mode. If the large display (1) was showing the message
'PauSE', the network job mode will end, but no job will be
loaded.
Exit Network Job Mode
h
Pressing any of these keys will cause the counter to
change to a new mode.
TP10243-3
2.7

Production Mode

Enter Run Mode and Select Large Display Content
0
These keys do not operate as mode select keys in
counter setup. In all other modes, the keys both select the
large display (1) contents and place the counter into run
mode. Pushing one of the buttons will light the button's
associated LED and cause the parameter to be displayed. If
both the input and output count keys are pressed simulta-
neously, then both LEDs go on and the waste count is
displayed. See Process Variable Definitions.

Table 12. Determining the Large Display Contents

When the folder is started the counter will start up in
the run mode, the normal operating mode of the counter.
In this mode, various job parameters can be displayed on
the large display (1) and the small display (2) shows the
gap length. The suction length display (3) is active in this
mode and shows the suction length as a percentage of sheet
length.
Gap Length Adjustment
+
The gap length adjustment keys allow the user to
change the current gap length. The range of adjustment is
0.2" to 98.0" (0.5 cm to 250 cm).
Suction Length Adjustment
+
The suction length adjustment keys allow the user to
change the amount of suction applied to the current sheet
length. The display shows the percentage in 5% steps. All
of the bars must be totaled to get the value. The range of
adjustment is 5% to 50% of the current sheet length.
PAGE 30
h
Large Display Contents
Output Count
h
Batch Count Down
h
Number of Batches
Current Rate
h
Input Count
h
Waste Count