Batch Output Time; Sheet Length; Gap Length; Suction Length - Baum 2020 Instruction Manual

1st station folder w/pile feed
Hide thumbs Also See for 2020:
Table of Contents

Advertisement

5.3 Batch Output Time

This parameter, accessible in the Batch Setup mode,
specifies the output duration or delay that will be used when
the Batch Count Down reaches zero.
Available ranges are determined by the Batch Output Type
selected. The Table below shows the ranges for each output
type.
Output
Type
Feed
Table
Delivery
Speed

Table 15. Output Delay and Duration

5.4 Sheet Length

This parameter, accessible in the Batch Setup mode,
specifies the length of the paper that will be fed into the
machine.
Available range is 6.0" to 59.0". 6.0" is the default
selection.

5.5 Gap Length

This parameter is accessible in Run mode and Learn
mode and specifies the length of gap to use between sheets
of paper that are fed into the machine.
Available range is 0.2" to 98.0". 2.0" is the default selec-
tion.

5.6 Suction Length

This parameter is accessible in Run mode and Learn
mode andspecifies the suction length used on a sheet of
paper that is fed into the machine.
Available range is 5% to 50% in 5% increments. 30% is the
default.
Delay
Min. Time
Max. Time
Not applicable
0.000 Sec.
1.000 Sec.
0.000 Sec.
1.000 Sec.
Not applicable
PAGE 33
Duration
Min. Time
Max. Time
0.0 Sec.
9.9 Sec.
100 ms
25 ms
0.00 Sec.
5.55 Sec.
TP10243-3

Advertisement

Table of Contents