1.3 Tapping the Transformer

Pass the power cable through the strain relief and the
hole provided in the control box. Connect the power cable
to the open terminals on the main disconnect in the control
box. The incoming ground wire should be attached to the
ground stud located in the lower right-hand corner of the
control box.
To tap the transformer, read the incoming voltage at the
main disconnect. Then move the wire numbered 11L1 on the
transformer to the corresponding tap on the transformer.
Tighten all screw connections and close the door before
switching the machine on.
A connector is provided for power connection to the
stacker. The stacker must be plugged into the socket for the
machine to operate, if not, install the blind plug attached to
the box.
A connector is provided for power connection to the
second station (8-page) fold unit. If no additional folding
station is to be connected, the connector must be closed off
with a blind plug.

1.4 Pump Connections

Connect the air hoses to the pump. The small diameter
hose is connected to the vacuum side of the pump. Connect
it to the barbed fitting above the ball valve on one end and
the other end to the vacuum solenoid valve on the pile feeder.
Connect the larger diameter hose to the remaining outlet
port on the pump and to the barbed fitting on the pile feeder
at the end of the blow bar.
Troubleshooting tips and actions required for the
display messages that may appear on the control readout
may be found the "Diagnostic Messages" section of the
manual.