Logic Board Status Indicators; Table 13. Reset Mode Selection; Table 14. Led Status Indicators - Baum 2020 Instruction Manual

1st station folder w/pile feed
Hide thumbs Also See for 2020:
Table of Contents

Advertisement

Reset Function
0
Pressing and holding this key will result in a reset
function being activated after a 5-second countdown. The
function is based on the current large display selection, see
table 12. The large display (1) will show countdown to
reset in this manner. When the button is pressed the
message 'CLr In 5' will show on the large display (1). At
one second intervals the display will progress through 'CLr
In 4', 'CLr In 3', 'CLr In 2', 'CLr In 1', and finally will
show 'CLEArEd' when the reset action is complete.
3.0

Logic Board Status Indicators

Several of the controller functions are monitored with
LED indicators located on the Logic Board (see Table 14).
The status of all other inputs are shown on the 8 Digit
display in Machine Setup mode (see Tables 1 - 6).
Reference Name
Designator
LED1
LED2
LED3
LED4
LED5
LED6
LED7
LED8
LED9
LED10
LED11

Table 14. LED Status Indicators

Tachometer Indicator
Not Used
Suction Indicator
K1
Pile Down
Pile Up
Pile Indicator
Logic +5VDC Supply
Isolated +5VDC Supply
Isolated +24VDC Supply
Kicker
Reset while showing Output Count will reset all job
variables.
Reset while showing batch data will reset Number
of Batches and reload the Batch Down Count.

Table 13. Reset mode Selection

Description
Tracks the Tachometer input.
Turns on when MKE output is activated.
Tracks the Suction output.
Status of Relay K1
Tracks the Pile down output.
Tracks the Pile up output.
Tracks the Pile outputs. If one of the Pile
outputs is on, this LED will be on.
Shows status of Logic +5VDC Supply
Shows status of Isolated +5VDC Supply
Shows status of Isolated +24VDC Supply
Turns on when kicker output is activated.
PAGE 31