System Messages And Run Messages; Power-Up Fault Messages; Table 16. Power Up Fault Messages - Baum 2020 Instruction Manual

1st station folder w/pile feed
Hide thumbs Also See for 2020:
Table of Contents

Advertisement

6.0 System Messages and Run Messages

6.1 Power-Up Fault Messages

Messages that are displayed during power on self-test. If PLC System Errors are shown in the display, call service.
ENGLISH
GERMAN
88888
88888
MEM TEST
MEM TEST MEM TEST Information The controller is performing its RAM test.
All Blank
All Blank
ID Fail
ID Fail
Error 1
Error 1
Error 2
Error 2
Error 3
Error 3
Error 4
Error 4
Error 5
Error 5
Error 6
Error 6

Table 16. Power Up Fault Messages

TP10243-3
CODES
TYPE
88888
Information The controller is performing its lamp test.
All Blank
PLC System The display board is not functioning.
Error
ID Fail
PLC System System cannot recognize the controller board.
Error
Error 1
PLC System The RAM test has found a bad memory location.
Error
Error 2
PLC System The Pile Safety Relay is stuck on or there is no power supply to the
Error
Error 3
PLC System There is power in the Pile Drive when it is off. Action: Check the
Error
Error 4
PLC System The 24VAC inputs have current before the Watchdog relay has
Error
Error 5
PLC System The membrane switch panel has a key pressed during the power
Error
Error 6
PLC System The Watchdog sense circuit indicates Watchdog-timer operational
Error
PAGE 34
DESCRIPTION
Cycle Power. If error persists, call service.
Action: Cycle Power, if error persists call service.
Action: Cycle Power, if error persists call service.
pile circuits. Action: Check the condition of Relay 1 (K1), Fuses
F1 and F2, and X18. Cycle Power. If error persists, call service.
condition of Relay 1 (K1), Fuses F1 and F2, and X18. Cycle
Power. If error persists, call service.
been activated. Action: Check for stuck push buttons, faulty
sensors, or loose connectors. Cycle Power. If error persists, call
service.
on self-test. Action: Cycle Power, if error persists call service.
before it has been started. Action: Cycle Power, if error persists
call service.

Advertisement