The center notches should seat on the second set of
locating pins. Pivot the fold plate hold-downs back into
position to secure the fold plates.
Turn the handwheel to be sure that the fold plates
are properly installed and not rubbing on the fold rolls.
Plug the fold pan connectors into the side frame.
(See figure 4.5-1)
Figure 4.5-1
WARNING
Do not operate machine without fold pans installed
in machine

5.0 ELECTRICAL ACCESS

WARNING
Turn off the main power switch(See figure 5.0-1).
Unplug the AC power cord before attempting any
electrical repair.
WARNING
Ensure all cables and hoses are properly located to
prevent any persons from tripping over them.
The electrical controls are located in the left-hand
side cover. The handwheel must be removed for access
to these controls.
The cover can be removed by taking out the four
screws located on the inside of the frame.
Main Power/Reset
Switch
Figure 5.0-1
PAGE 23

6.0 OPERATION

6.1 The Main Power/Reset Switch

The main power/reset switch (Figure 6.1-1) will com-
pletely shut off all power to the operating system. This will
stop everything immediately.

6.2 Starting the Production Job

The production job may be started after preparing the
folder by:
Setting the sheet size
Loading the feed table
Selecting the fold type
Setting Cross Carrier Side Guide
Folding may be stopped by pressing the "SHEET
START" button a 2nd time on the Parallel Unit.

6.3 Check Squareness of Fold

Examine the folded sheets on the stacker to make sure
that you are getting an even and square fold.
There is a skew adjustment on each plate to adjust for a
square fold on paper that is not cut square