Make Ready Mode; Table 10. Suction Mode Symbols; Table 11. Suction Length Function - Baum 2020 Instruction Manual

1st station folder w/pile feed
Hide thumbs Also See for 2020:
Table of Contents

Advertisement

If P06 is set to 0 (no knife is active) and 10 cm /4.0 inches. If
P06 is setting to 1, knifes are active.
Gap Length Adjustment
+
The minus and plus keys adjust the gap length. The gap
length range is 0.2" to 98.0" (0.5cm to 250cm).
Suction Length Adjustment
+
This is the same as in run mode
The suction length adjustment keys allow the user to
change the amount of suction applied to the current sheet
length. The display shows the percentage in 5% steps. All
of the bars must be totaled to get the value. The range of
adjustment is 5% to 50% of the current sheet length. If the
suction length is manually adjusted while the Learn Mode
LED is on, the suction length will no longer be the Single
Sheet suction length of 6.0". The new suction length will
be based on the current sheet length and suction setting.
TWT-180 Mode
Leading Edge Control
Leading and Trailing Edge Control

Table 10. Suction Mode Symbols

Sheet Length Setting
Greater than or equal to 30 cm.
Less than 30 cm., and greater than or equal to 27 cm.
Less than 27 cm., and greater than or equal to 24 cm.
Less than 24 cm., and greater than or equal to 21 cm.
Less than 21 cm.

Table 11. Suction Length Function

Exit Learn Mode
0
h
Pressing any of these keys will cause the controller to
change to a new mode.
Select Suction Mode
+
These keys toggle between automatic control and cycle
mode. In the cycle mode, the suction valve will be on for
the suction length and off for the remainder of the sheet
length plus the gap length. No adjustments are made for
slipped sheets or process changes. The automatic mode
corrects for process changes and controls the timing of the
suction valve to maintain the user-selected gap. If the gap
is less than 1.5" (4.0 cm), the right hand decimal point of
the small display (2) will flash and the Leading edge
control will be active. If the gap is greater than or equal to
1.5" (4.0 cm), full Leading and Trailing edge control is
maintained. Refer to table 10 for suction mode symbol
definitions.
Sheet Length Adjustment
+
The sheet length adjustment keys allow the user to
override the automatic Learn Mode setting. When the user
changes the sheet length, the suction length will be
adjusted according to table 11. If a different suction length
is desired, the value may be overridden with the suction
length adjustment keys. The sheet length range is 10 cm /4
inches to 250 cm / 98.5 inches.
Resultant Suction Length Percentage
30% of Sheet Length
25% of Sheet Length
20% of Sheet Length
15% of Sheet Length
10% of Sheet Length.

2.5 Make Ready Mode

This key places the controller in the make ready mode.
The key LED goes on. In this mode the folder will only
feed single sheets and a batching output is issued for every
two sheets fed. This allows the operator to easily set up the
batching time.