6.2 Run Time Fault Messages

Run time fault messages are only displayed when the unit is in Run mode. Fault errors can still occur, but the corresponding
fault message will not be displayed until the unit is switched to Run mode. Run time fault messages are PLC System Errors
or errors in the whole Electric System. It is necessary to call a technician or service.
ENGLISH
GERMAN
DCT X.X.X
DCT X.X.X
K5 Relay
K5 Relay
Button
Taste
Watchdog
Watchdog
No Tach
Impuls
Overload
Uberlast
Pile Err
Spg.Uber
Overrun
Uberlauf
nd
2
Stat
2Station
Suction
Saugtakt

Table 17. Run Time Fault Messages

CODES
TYPE
DCT X.X.X Information
Error 7
PLC System
Error
Error 8
Electrical
System
Error
Error 9
PLC System
Error
Error10
Electrical
System
Error
Error11
Electrical
System
Error
Error12
Electrical
System
Error
Error13
Electrical
System
Error
Error14
Electrical
System
Error
Error15
Electrical
System
Error
DESCRIPTION
This is the Software-Version(X.X.X)
Note: do not push any buttons until this message has been
cleared from the display
The drive stop relay, K5, is not responding to the controller.
Action: Call service.
A push button is in the wrong state during the version message
display. Action: Check Buttons & Cycle Power. If error
persists call service.
The Watchdog Timer has elapsed without being serviced.
Action: Cycle Power. If error persists call service.
The Machine Tachometer is reading a velocity outside of the
range 10 – 230 meters per minute, while the main drive should
be running. Action: Check the electric. If error persists call
service.
A Thermal Overload has been tripped.
Action: Check the electric. If error persists call service.
The Pile Safety Relay is stuck on or there is no power supply to
the pile circuits. Action: Check the condition of Relay 1 (K1),
Fuses F1 and F2, and X18, then cycle Power. If error persists
call service.
The Pile Table has moved past its safety stops. Action: Check
the limit switches, pile table, and wiring. If error persists call
service.
The Emergency Stop, Wrong Sheet, and Thermal Overload
sense circuits are all indicating failure. Likely cause is Second
Station connector problems. Action: Check the Second Station
Connector, connector X22, and each individual circuit. If error
persists call service.
Short circuit on Suction controller. Action: Check the electrics.
If error persists call service.