Operating The Sensormatic Deactivation System; Normal Operation - NCR RealScan 7875-7000 Installation Manual

Table of Contents

Advertisement

NCR RealScan 7875-7000/8000 Installation Guide

Normal Operation

The operating procedures can vary according to the parameter settings. The following procedure
assumes the Sensormatic parameters are set to the following values.
Following procedure assumes the RealScan 7875 and the Sensormatic ScanMax™ Pro
Controller are turned on and functioning properly.
1. Pass an item across the scanner.
2. As the barcode goes through the scan zone, the RealScan 7875 reads it.
3. As the security tag goes through the Sensormatic deactivation zone, the Sensormatic system
4. If the security tag is not deactivated, a clicking tone is generated. Place the item against the
32 of 56
Security tag deactivation function is enabled.
Security tag deactivated tone is enabled.
Security tag detected tone is enabled.
deactivates the security tag. At this time the NCR RealScan 7875 sounds the Good Read
Tone.
gray label. The clicking tone stops when the security tag is deactivated.
Note: The security tag must be detected by the Sensormatic system before the Scan Enable
Timer expires or it is not deactivated even when it does come into the deactivation zone. In
this case, the Security Tag Detected Tone sounds while the tag is in the deactivation zone.
The sound is similar to a Geiger counter. When this condition occurs, the security tag must
be deactivated manually.
Operating the Sensormatic
Deactivation System
06/03
AIP-00342
Release B

Hide quick links: