Replacing The Door Seal; Replacing The Halogen Lamp - Rational CombiMaster Plus 61 Original Operating Instructions

Combi oven
Table of Contents

Advertisement

Maintenance

Replacing the door seal

The door seal is fitted in a groove on the cooking
cabinet.
- Pull the old seal out of the groove.
- Clean the guide rail.
- Insert new seal into the groove (moisten the
retaining lips with soapy water).
- The rectangular part of the seal must be seated fully
in the holding frame.
Cooking cabinet seal:
6 x 1/1 GN
6 x 2/1 GN
10 x 1/1 GN
10 x 2/1 GN
20 x 1/1 GN
20 x 2/1 GN
 

Replacing the halogen lamp

First switch off the unit at the mains!
- Cover the unit drain in the cooking cabinet.
- Remove the frame with glass and seal.
- Replace halogen bulb (article no.: 3024.0201), do
not touch the bulb with your hands).
- Replace sealing frame as well (article no.:
40.00.094).
- Screw the frame in place with glass and seals.
78 / 85
No: 20.00.394
No: 20.00.395
No: 20.00.396
No: 20.00.397
No: 20.00.398
No: 20.00.399
 

Hide quick links:

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the CombiMaster Plus 61 and is the answer not in the manual?

Questions and answers

Cosmis
March 20, 2025

I need trouble shooting manually

1 comments:
Mr. Anderson
March 20, 2025

To manually troubleshoot the Rational CombiMaster Plus 61, follow these steps:

1. Cooking Cabinet Light Not Working
- Cause: Halogen lamp is defective.
- Solution: Replace the lamp (refer to the “Maintenance” section of the manual).

2. Low Water Warning ("OPEn H2O" on Display)
- Cause: Water tap is closed or the water intake filter is clogged.
- Solution:
- Open the water tap.
- Check and clean the water intake filter:
- Close the water tap.
- Unscrew the water intake on the unit.
- Remove and clean the filter.
- Reinsert the filter, reconnect the intake, and check for leaks.

3. Water Running Out from the Bottom of the Unit
- Cause: The unit is not level or the drain is blocked.
- Solution:
- Level the unit using a spirit level (refer to the Installation Manual).
- Remove and clean the outlet (HT pipe) at the back of the unit.
- If blockages recur, ensure the outlet pipe is installed correctly according to the installation instructions.

4. Unit Not Functioning
- Cause: External main power issue or other faults.
- Solution:
- Check the external power supply and ensure the unit is connected properly.
- If the issue persists, further troubleshooting or service may be required.

For additional troubleshooting, refer to the manual or contact professional service if necessary.