Explanation Of The Pictograms - Rational CombiMaster Plus 61 Original Operating Instructions

Combi oven
Table of Contents

Advertisement

Explanation of the pictograms

Danger!
Imminently hazardous
situation, which, if not
avoided, will result in severe
injuries or death.
Corrosive
substances
Note:
Damage may be caused if
this is ignored.
The maximum rack height is
160 cm.
Warning!
Potentially hazardous
situation, which, if not
avoided, may result in
serious injury or death.
Risk of fire!
Handy tips for everyday
use.
 
Caution!
Potentially hazardous
situation, which, if not
avoided, may result in slight
or minor injuries.
Risk of burning!
Read the manual carefully
prior to initial start-up.
 
7 / 85

Hide quick links:

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the CombiMaster Plus 61 and is the answer not in the manual?

Questions and answers

Cosmis
March 20, 2025

I need trouble shooting manually

1 comments:
Mr. Anderson
March 20, 2025

To manually troubleshoot the Rational CombiMaster Plus 61, follow these steps:

1. Cooking Cabinet Light Not Working
- Cause: Halogen lamp is defective.
- Solution: Replace the lamp (refer to the “Maintenance” section of the manual).

2. Low Water Warning ("OPEn H2O" on Display)
- Cause: Water tap is closed or the water intake filter is clogged.
- Solution:
- Open the water tap.
- Check and clean the water intake filter:
- Close the water tap.
- Unscrew the water intake on the unit.
- Remove and clean the filter.
- Reinsert the filter, reconnect the intake, and check for leaks.

3. Water Running Out from the Bottom of the Unit
- Cause: The unit is not level or the drain is blocked.
- Solution:
- Level the unit using a spirit level (refer to the Installation Manual).
- Remove and clean the outlet (HT pipe) at the back of the unit.
- If blockages recur, ensure the outlet pipe is installed correctly according to the installation instructions.

4. Unit Not Functioning
- Cause: External main power issue or other faults.
- Solution:
- Check the external power supply and ensure the unit is connected properly.
- If the issue persists, further troubleshooting or service may be required.

For additional troubleshooting, refer to the manual or contact professional service if necessary.

This answer is automatically generated

This manual is also suitable for:

Combimaster plus 201

Table of Contents

Save PDF