Safety Instructions
Warning!
Gas units only
- If your appliance is installed under an extractor hood, this must be switched on when the
appliance is in use – Combustion gases!
- If your appliance is connected to a chimney, the flue duct must be cleaned in compliance
with specific regional regulations – risk of fire. (Contact your installer.)
- Do not put objects on your unit's exhaust pipes – risk of fire.
- Do not let objects block or obstruct the area below the unit's base – risk of fire.
- The unit must only be used in still conditions – risk of fire.
 
What to do if you smell gas:
- Shut off the gas supply immediately
- Do not touch any electrical controls
- Make sure the area is well ventilated
- Avoid naked flames or sparking
- Use an external telephone to notify the appropriate gas supplier (if the gas supplier is
unobtainable call the emergency services on 999).
 
12 / 85

Hide quick links:

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the CombiMaster Plus 61 and is the answer not in the manual?

Questions and answers

Cosmis
March 20, 2025

I need trouble shooting manually

1 comments:
Mr. Anderson
March 20, 2025

To manually troubleshoot the Rational CombiMaster Plus 61, follow these steps:

1. Cooking Cabinet Light Not Working
- Cause: Halogen lamp is defective.
- Solution: Replace the lamp (refer to the “Maintenance” section of the manual).

2. Low Water Warning ("OPEn H2O" on Display)
- Cause: Water tap is closed or the water intake filter is clogged.
- Solution:
- Open the water tap.
- Check and clean the water intake filter:
- Close the water tap.
- Unscrew the water intake on the unit.
- Remove and clean the filter.
- Reinsert the filter, reconnect the intake, and check for leaks.

3. Water Running Out from the Bottom of the Unit
- Cause: The unit is not level or the drain is blocked.
- Solution:
- Level the unit using a spirit level (refer to the Installation Manual).
- Remove and clean the outlet (HT pipe) at the back of the unit.
- If blockages recur, ensure the outlet pipe is installed correctly according to the installation instructions.

4. Unit Not Functioning
- Cause: External main power issue or other faults.
- Solution:
- Check the external power supply and ensure the unit is connected properly.
- If the issue persists, further troubleshooting or service may be required.

For additional troubleshooting, refer to the manual or contact professional service if necessary.

This answer is automatically generated