Maintenance

Air filter service

Table-top units type 6 x 1/1 GN, 6 x 2/1 GN, 10 x 1/1
GN and 10 x 2/1 GN:
Loosen the air filter by pressing the frame in the two
roughened spots. Tilt the filter down and remove it
completely from the unit.
Clean the air filter in the dishwasher (not with CleanJet
!) and then allow it to dry. If the air filter is still very
®
sticky and soiled after cleaning it will have to be
replaced.
Then insert the air filter with the rear hooks in the holes
on the underside of the unit first, and then lock in place
by pushing from bottom to top (opposite procedure to
removing the filter).
Air filter no.: 40.03.461
Floor units type 20 x 1/1 GN and 20 x 2/1 GN:
Please contact your Service partner for replacement of
the air filters on the floor units 20 x 1/1 GN and 20 x 2/1
GN.
77 / 85

Hide quick links:

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the CombiMaster Plus 61 and is the answer not in the manual?

Questions and answers

Cosmis
March 20, 2025

I need trouble shooting manually

1 comments:
Mr. Anderson
March 20, 2025

To manually troubleshoot the Rational CombiMaster Plus 61, follow these steps:

1. Cooking Cabinet Light Not Working
- Cause: Halogen lamp is defective.
- Solution: Replace the lamp (refer to the “Maintenance” section of the manual).

2. Low Water Warning ("OPEn H2O" on Display)
- Cause: Water tap is closed or the water intake filter is clogged.
- Solution:
- Open the water tap.
- Check and clean the water intake filter:
- Close the water tap.
- Unscrew the water intake on the unit.
- Remove and clean the filter.
- Reinsert the filter, reconnect the intake, and check for leaks.

3. Water Running Out from the Bottom of the Unit
- Cause: The unit is not level or the drain is blocked.
- Solution:
- Level the unit using a spirit level (refer to the Installation Manual).
- Remove and clean the outlet (HT pipe) at the back of the unit.
- If blockages recur, ensure the outlet pipe is installed correctly according to the installation instructions.

4. Unit Not Functioning
- Cause: External main power issue or other faults.
- Solution:
- Check the external power supply and ensure the unit is connected properly.
- If the issue persists, further troubleshooting or service may be required.

For additional troubleshooting, refer to the manual or contact professional service if necessary.