Safety Instructions - Rational CombiMaster Plus 61 Original Operating Instructions

Combi oven
Table of Contents

Advertisement

Safety Instructions

Keep this manual handy so that it can always be consulted by anyone using the unit.
This unit may not be used by children or anyone with limited physical, sensory or mental
abilities or a lack of experience and/or knowledge, unless these people are supervised by
someone responsible for safety.
Only use your hands to operate the controls. Damage caused by the use of pointed, sharp
or other objects will invalidate the warranty.
We recommend regular training of your staff to avoid the risk of accident or damage to the
unit. Operators must also receive regular safety instruction.
Warning!
Daily checks before switching on and use
- Lock the air baffle at the top and bottom as per the instructions - risk of injury from the
rotating fan wheel.
- Make sure that the hanging racks or mobile oven rack are correctly locked in place in the
cooking cabinet – Containers with hot liquids can fall through or slip out of the cooking
cabinet – risk of burns.
- Make sure that there are no residues of cleaning agents in the cooking cabinet before you
start cooking with the unit. Remove any cleaning agent residue and rinse thoroughly with
a hand shower – risk of chemical burns.
 
10 / 85

Hide quick links:

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the CombiMaster Plus 61 and is the answer not in the manual?

Questions and answers

Cosmis
March 20, 2025

I need trouble shooting manually

1 comments:
Mr. Anderson
March 20, 2025

To manually troubleshoot the Rational CombiMaster Plus 61, follow these steps:

1. Cooking Cabinet Light Not Working
- Cause: Halogen lamp is defective.
- Solution: Replace the lamp (refer to the “Maintenance” section of the manual).

2. Low Water Warning ("OPEn H2O" on Display)
- Cause: Water tap is closed or the water intake filter is clogged.
- Solution:
- Open the water tap.
- Check and clean the water intake filter:
- Close the water tap.
- Unscrew the water intake on the unit.
- Remove and clean the filter.
- Reinsert the filter, reconnect the intake, and check for leaks.

3. Water Running Out from the Bottom of the Unit
- Cause: The unit is not level or the drain is blocked.
- Solution:
- Level the unit using a spirit level (refer to the Installation Manual).
- Remove and clean the outlet (HT pipe) at the back of the unit.
- If blockages recur, ensure the outlet pipe is installed correctly according to the installation instructions.

4. Unit Not Functioning
- Cause: External main power issue or other faults.
- Solution:
- Check the external power supply and ensure the unit is connected properly.
- If the issue persists, further troubleshooting or service may be required.

For additional troubleshooting, refer to the manual or contact professional service if necessary.