Descaling the steam generator
Amounts of descaler for gas appliances
6 x 1/1 GN
4 litre
 
6 x 2/1 GN
6.5 litre
step
15
16
17
18
19
20
10 x 1/1 GN
7 litre
 
10 x 2/1 GN
9 litre
info/button
20 x 1/1 GN
8 litre
 
20 x 2/1 GN
11 litre
instructions
Remove descaler accessories from the cooking
cabinet (hand pump and canister).
 
Thoroughly rinse descaling fluid in cabinet and
descaling accessories with water.
 
Re-insert the air baffle and hanging rack and
lock them in place.
Appears on the display.
Close the cooking cabinet door. The length of
the descaling phase is displayed.
The steam generator is automatically rinsed
several times, the unit then automatically
switches to "steam".
"End" appears on the display when descaling is
complete.
You exit the descaling process by selecting a
cooking mode. You can now use your unit for
cooking.
73 / 85

Hide quick links:

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the CombiMaster Plus 61 and is the answer not in the manual?

Questions and answers

Cosmis
March 20, 2025

I need trouble shooting manually

1 comments:
Mr. Anderson
March 20, 2025

To manually troubleshoot the Rational CombiMaster Plus 61, follow these steps:

1. Cooking Cabinet Light Not Working
- Cause: Halogen lamp is defective.
- Solution: Replace the lamp (refer to the “Maintenance” section of the manual).

2. Low Water Warning ("OPEn H2O" on Display)
- Cause: Water tap is closed or the water intake filter is clogged.
- Solution:
- Open the water tap.
- Check and clean the water intake filter:
- Close the water tap.
- Unscrew the water intake on the unit.
- Remove and clean the filter.
- Reinsert the filter, reconnect the intake, and check for leaks.

3. Water Running Out from the Bottom of the Unit
- Cause: The unit is not level or the drain is blocked.
- Solution:
- Level the unit using a spirit level (refer to the Installation Manual).
- Remove and clean the outlet (HT pipe) at the back of the unit.
- If blockages recur, ensure the outlet pipe is installed correctly according to the installation instructions.

4. Unit Not Functioning
- Cause: External main power issue or other faults.
- Solution:
- Check the external power supply and ensure the unit is connected properly.
- If the issue persists, further troubleshooting or service may be required.

For additional troubleshooting, refer to the manual or contact professional service if necessary.