Rational CombiMaster Plus 61 Original Operating Instructions page 21

Combi oven
Table of Contents

Advertisement

Notes on using your unit
Working with mobile oven racks, mobile plate racks
and transport trolleys for table-top units (option))
- Remove the hanging rack as described above.
- Place the run-in rail on the fixing provided on the unit's
base. Make sure it is fixed accurately in place (4 pins).
- Remember that the unit must be matched to the exact
height of the transport trolley and must be levelled.
- Move the transport trolley as far as it will go on the
run-in rail and make sure that the transport trolley is
correctly locked on the unit.
- Push the mobile oven rack or mobile plate rack into
the unit as far as it will go, and check that the locking
mechanism in the unit is working correctly.
- To remove the mobile oven rack or mobile plate rack,
release the locking mechanism and pull the rack out of
the cooking cabinet. First insert the core temperature
probe with the run-in rail in the park position.
- Make sure that the mobile oven rack or mobile plate
rack is securely locked on the transport trolley during
transportation.
21 / 85

Hide quick links:

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the CombiMaster Plus 61 and is the answer not in the manual?

Questions and answers

Cosmis
March 20, 2025

I need trouble shooting manually

1 comments:
Mr. Anderson
March 20, 2025

To manually troubleshoot the Rational CombiMaster Plus 61, follow these steps:

1. Cooking Cabinet Light Not Working
- Cause: Halogen lamp is defective.
- Solution: Replace the lamp (refer to the “Maintenance” section of the manual).

2. Low Water Warning ("OPEn H2O" on Display)
- Cause: Water tap is closed or the water intake filter is clogged.
- Solution:
- Open the water tap.
- Check and clean the water intake filter:
- Close the water tap.
- Unscrew the water intake on the unit.
- Remove and clean the filter.
- Reinsert the filter, reconnect the intake, and check for leaks.

3. Water Running Out from the Bottom of the Unit
- Cause: The unit is not level or the drain is blocked.
- Solution:
- Level the unit using a spirit level (refer to the Installation Manual).
- Remove and clean the outlet (HT pipe) at the back of the unit.
- If blockages recur, ensure the outlet pipe is installed correctly according to the installation instructions.

4. Unit Not Functioning
- Cause: External main power issue or other faults.
- Solution:
- Check the external power supply and ensure the unit is connected properly.
- If the issue persists, further troubleshooting or service may be required.

For additional troubleshooting, refer to the manual or contact professional service if necessary.

This answer is automatically generated