Features - Rational CombiMaster Plus 61 Original Operating Instructions

Combi oven
Table of Contents

Advertisement

Features

Unit number
(visible only when door is open))
Draft diverter (optional)
(gas units only)
Interior lighting
Unit door with double glass panel
Door handle
Table-top units: One-handed operation
with slam function
Floor units: One-handed operation
Unlocking device to open double
glass door panel (inside)
Integrated and self-emptying door drip
pan (inside)
Drip collector connected directly to
unit drain
CombiMaster Plus 61 on thermocabinet
Unit feet (height-adjustable)
Rating plate
(contains important data such as power
consumption, type of gas, voltage,
number of phases and frequency, as well
as the unit type, unit number and option
number)
Control panel
Protective cover for electrical
installation area
Hand shower (optional)
(with automatic retraction system)
Run-in guide (table-top units)
Air filter table-top unit (installation area
ventilation)
Air filter floor unit (installation area
ventilation, back of the unit)
CombiMaster Plus 201
18 / 85

Hide quick links:

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the CombiMaster Plus 61 and is the answer not in the manual?

Questions and answers

Cosmis
March 20, 2025

I need trouble shooting manually

1 comments:
Mr. Anderson
March 20, 2025

To manually troubleshoot the Rational CombiMaster Plus 61, follow these steps:

1. Cooking Cabinet Light Not Working
- Cause: Halogen lamp is defective.
- Solution: Replace the lamp (refer to the “Maintenance” section of the manual).

2. Low Water Warning ("OPEn H2O" on Display)
- Cause: Water tap is closed or the water intake filter is clogged.
- Solution:
- Open the water tap.
- Check and clean the water intake filter:
- Close the water tap.
- Unscrew the water intake on the unit.
- Remove and clean the filter.
- Reinsert the filter, reconnect the intake, and check for leaks.

3. Water Running Out from the Bottom of the Unit
- Cause: The unit is not level or the drain is blocked.
- Solution:
- Level the unit using a spirit level (refer to the Installation Manual).
- Remove and clean the outlet (HT pipe) at the back of the unit.
- If blockages recur, ensure the outlet pipe is installed correctly according to the installation instructions.

4. Unit Not Functioning
- Cause: External main power issue or other faults.
- Solution:
- Check the external power supply and ensure the unit is connected properly.
- If the issue persists, further troubleshooting or service may be required.

For additional troubleshooting, refer to the manual or contact professional service if necessary.

This answer is automatically generated