Rational CombiMaster Plus 61 Original Operating Instructions page 54

Combi oven
Table of Contents

Advertisement

Program mode
- If the display flashes, it means the program slot is vacant.
- The remaining cooking time is shown during operation in the "cooking time/core temperature"
display. If the program includes a step with core temperature, the remaining time is only shown
when this step has been finished.
- It is not possible to change between core temperature and cooking time or vice versa.
- Stop the program by opening the cooking cabinet door. Cancel the program by choosing a
different cooking mode or switching the appliance off.
- To change the settings later, turn the selection button to the zero setting first (at the top) and
then adjust the required time or temperature.
If you press the button during current operating you will change the cooking
time of the current step. The new value is not saved.
If you press the button during current operating you will change the core
temperature of the current step. The new value is not saved.
54 / 85

Hide quick links:

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the CombiMaster Plus 61 and is the answer not in the manual?

Questions and answers

Cosmis
March 20, 2025

I need trouble shooting manually

1 comments:
Mr. Anderson
March 20, 2025

To manually troubleshoot the Rational CombiMaster Plus 61, follow these steps:

1. Cooking Cabinet Light Not Working
- Cause: Halogen lamp is defective.
- Solution: Replace the lamp (refer to the “Maintenance” section of the manual).

2. Low Water Warning ("OPEn H2O" on Display)
- Cause: Water tap is closed or the water intake filter is clogged.
- Solution:
- Open the water tap.
- Check and clean the water intake filter:
- Close the water tap.
- Unscrew the water intake on the unit.
- Remove and clean the filter.
- Reinsert the filter, reconnect the intake, and check for leaks.

3. Water Running Out from the Bottom of the Unit
- Cause: The unit is not level or the drain is blocked.
- Solution:
- Level the unit using a spirit level (refer to the Installation Manual).
- Remove and clean the outlet (HT pipe) at the back of the unit.
- If blockages recur, ensure the outlet pipe is installed correctly according to the installation instructions.

4. Unit Not Functioning
- Cause: External main power issue or other faults.
- Solution:
- Check the external power supply and ensure the unit is connected properly.
- If the issue persists, further troubleshooting or service may be required.

For additional troubleshooting, refer to the manual or contact professional service if necessary.

This answer is automatically generated

Subscribe to Our Youtube Channel

This manual is also suitable for:

Combimaster plus 201

Table of Contents

Save PDF