Combination mode
The two operating modes "steam" and "dry heat" are combined. This combination creates a
hot humid cabinet climate for especially intensive cooking. You can set the cooking cabinet
temperature from 30 °C to 300 °C . You can set the cooking cabinet climate if necessary.
Cooking methods: Roasting, baking, finishing.
step
1
2
3
4
5
6
5
6
info/button
instructions
Choose the "combination" mode.
To preheat, turn the selection button anti-
clockwise as far as it will go. "PreEH" is shown
on the display. The end of preheating is
indicated by an acoustic signal and "LoAd" on
the display.
Set the required temperature.
Select the required cooking cabinet humidity or
work with the default setting.
Press the button to set the cooking time.
Set the required cooking time. For continuous
operation, please turn the selection button
clockwise as far as it will go.
Or alternatively press the "core temperature"
button and set the required core temperature.
Choose the required core temperature.
41 / 85
Need help?
Do you have a question about the CombiMaster Plus 61 and is the answer not in the manual?
Questions and answers
I need trouble shooting manually
To manually troubleshoot the Rational CombiMaster Plus 61, follow these steps:
1. Cooking Cabinet Light Not Working
- Cause: Halogen lamp is defective.
- Solution: Replace the lamp (refer to the “Maintenance” section of the manual).
2. Low Water Warning ("OPEn H2O" on Display)
- Cause: Water tap is closed or the water intake filter is clogged.
- Solution:
- Open the water tap.
- Check and clean the water intake filter:
- Close the water tap.
- Unscrew the water intake on the unit.
- Remove and clean the filter.
- Reinsert the filter, reconnect the intake, and check for leaks.
3. Water Running Out from the Bottom of the Unit
- Cause: The unit is not level or the drain is blocked.
- Solution:
- Level the unit using a spirit level (refer to the Installation Manual).
- Remove and clean the outlet (HT pipe) at the back of the unit.
- If blockages recur, ensure the outlet pipe is installed correctly according to the installation instructions.
4. Unit Not Functioning
- Cause: External main power issue or other faults.
- Solution:
- Check the external power supply and ensure the unit is connected properly.
- If the issue persists, further troubleshooting or service may be required.
For additional troubleshooting, refer to the manual or contact professional service if necessary.
This answer is automatically generated