Descaling the steam generator
step
12
Amounts of descaler for electric appliances
6 x 1/1 GN
3.5 liter
 
6 x 2/1 GN
6 liter
72 / 85
info/button
10 x 1/1 GN
6 liter
 
10 x 2/1 GN
8,5 liter
instructions
Warning!
Aggressive chemical fluid – risk of chemical
burns.
There may be residues of the descaling fluid
in the hoses. Rinse the descaling accessories
thoroughly with water.
Wear: protective clothing, safety goggles, gloves
and facemask.
Place canister of descaling fluid in the cooking
cabinet and run the hose into the canister.
 
Note:
Descaling fluid reacts with lime and can foam
over.
 
Very slowly fill with descaling fluid using the unit
manufacturer's descaling pump.
20 x 1/1 GN
9 liter
 
20 x 2/1 GN
11.5 liter

Hide quick links:

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the CombiMaster Plus 61 and is the answer not in the manual?

Questions and answers

Cosmis
March 20, 2025

I need trouble shooting manually

1 comments:
Mr. Anderson
March 20, 2025

To manually troubleshoot the Rational CombiMaster Plus 61, follow these steps:

1. Cooking Cabinet Light Not Working
- Cause: Halogen lamp is defective.
- Solution: Replace the lamp (refer to the “Maintenance” section of the manual).

2. Low Water Warning ("OPEn H2O" on Display)
- Cause: Water tap is closed or the water intake filter is clogged.
- Solution:
- Open the water tap.
- Check and clean the water intake filter:
- Close the water tap.
- Unscrew the water intake on the unit.
- Remove and clean the filter.
- Reinsert the filter, reconnect the intake, and check for leaks.

3. Water Running Out from the Bottom of the Unit
- Cause: The unit is not level or the drain is blocked.
- Solution:
- Level the unit using a spirit level (refer to the Installation Manual).
- Remove and clean the outlet (HT pipe) at the back of the unit.
- If blockages recur, ensure the outlet pipe is installed correctly according to the installation instructions.

4. Unit Not Functioning
- Cause: External main power issue or other faults.
- Solution:
- Check the external power supply and ensure the unit is connected properly.
- If the issue persists, further troubleshooting or service may be required.

For additional troubleshooting, refer to the manual or contact professional service if necessary.