Rational CombiMaster Plus 61 Original Operating Instructions page 4

Combi oven
Table of Contents

Advertisement

CombiMaster – the power pack
Dear user,
 
Congratulations on your decision to purchase a CombiMaster
 
The new CombiMaster
and offers enticing functions that ensure outstanding cooking results every time: crispy
crusts, succulent roasts, intensive flavours and colours. The rotary button operation is
easy, clear and robust. Your CombiMaster
service in your kitchen.
 
We give a 24 month warranty calculated from the date of initial installation, providing you
have filled in the warranty registration for your appliance completely and correctly. You
can do this conveniently online at www.rational-online.com/warranty or using the enclosed
postcard. The warranty excludes glass damage, light bulbs and seals as well as damage
caused by improper installation, use, maintenance, repair or descaling.
 
Happy cooking!
 
Your
RATIONAL AG
 
We reserve the right to make technical changes in the interest of progress!
Dealer:
Unit number:
Plus stands for mature technology and excellent workmanship,
®
Plus will give you many years of reliable
®
Installer:
installed on:
 
Plus!
®

Hide quick links:

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the CombiMaster Plus 61 and is the answer not in the manual?

Questions and answers

Cosmis
March 20, 2025

I need trouble shooting manually

1 comments:
Mr. Anderson
March 20, 2025

To manually troubleshoot the Rational CombiMaster Plus 61, follow these steps:

1. Cooking Cabinet Light Not Working
- Cause: Halogen lamp is defective.
- Solution: Replace the lamp (refer to the “Maintenance” section of the manual).

2. Low Water Warning ("OPEn H2O" on Display)
- Cause: Water tap is closed or the water intake filter is clogged.
- Solution:
- Open the water tap.
- Check and clean the water intake filter:
- Close the water tap.
- Unscrew the water intake on the unit.
- Remove and clean the filter.
- Reinsert the filter, reconnect the intake, and check for leaks.

3. Water Running Out from the Bottom of the Unit
- Cause: The unit is not level or the drain is blocked.
- Solution:
- Level the unit using a spirit level (refer to the Installation Manual).
- Remove and clean the outlet (HT pipe) at the back of the unit.
- If blockages recur, ensure the outlet pipe is installed correctly according to the installation instructions.

4. Unit Not Functioning
- Cause: External main power issue or other faults.
- Solution:
- Check the external power supply and ensure the unit is connected properly.
- If the issue persists, further troubleshooting or service may be required.

For additional troubleshooting, refer to the manual or contact professional service if necessary.