6. Install the FCA2214 HBA driver on the new kernel by entering:
7. For Red Hat Linux Advanced Server/Enterprise Server, run the provided
8. Remove the MSA1000 Support Software CD from the CD-ROM drive and
9. Repeat these procedures for each Linux server that will access the MSA1000.
10. Connect the MSA1000 to the SAN, if it is not already connected.
Compiling a Driver from Source Code
If you need to build your own FCA2214 HBA driver module from source code or
manually patch the Linux kernel, refer to InstallNotes.txt in the /LINUX directory
on the MSA1000 Support Software CD.
MSA1000 Installation Guide
rpm -Uvh rmp filename
where rpm filename is the name of the rpm file for your distribution of
Linux.
After a few minutes, the following messages are displayed:
Attempting to load qla2200 ..... FAILED
Attempting to load qla2300 ..... OK
script to modify the SCSI blacklist.
a. Navigate to the
/opt/hp/storage_drivers/qla604/utils
b. Enter the command scripname
c. Follow the on-screen instructions to complete the update.
reboot your server.
Configuration Procedures - for Linux Environments
edit_initrd.redhat
directory.
.
65