Operator Menu Setup - Siemens MAG 1100 Handbook

Electromagnetic flowmeters
Table of Contents

Advertisement

SITRANS F M MAGFLO
8.4.9

Operator menu setup

8. Commissioning
The upper line is always active and can never be deselected.
The two lower lines are for individual operator information. Information which the operator can scroll
through with the forward key.
A closed lock key in the operator menu setup, means that the menu is enabled when viewing
the operator menu.
An open lock key symbol, means that the menu is not available in the operator menu.
The middle line can either be used as a heading "Text line" for the lower line, or as a flow reading.
A flow reading can be individually selected for each menu.
The lower line may be used for an additional flow reading to the reading already available in the
upper line.
DKFD.PS.027.W3.02
Text means that the text for the chosen measured value is
shown.
For example if text is chosen in line 2 and flow rate is chosen in
line 3, the text "flow rate" is shown in line 2 and the measured
flow rate value is show in line 3.