SITRANS F M MAGFLO

2.5.1 Signal converter MAG 5000 (DN 6 to DN 1200)

Current output
Current
Load
Time constant
Digital output
Frequency
Time constant
Active
Passive
Relay
Time constant
Load
Digital input
Activation time
Current
Functions
Galvanic isolation
Cut-off
Low flow
Empty pipe
Totalizer
Display
Time constant
Zero point adjustment
Electrode input impedance
Excitation frequency
Ambient temperature
Custody transfer approval
MAG 5000 CT
Communication
Standard
Optional
Compact
Enclosure material
Enclosure rating
Mechanicalload
19" insert
Enclosure material
Enclosure rating
Mechanical load
EMC performance
Supply voltage
Power consumption
1
) Special cable required in separate mounted installation
2. Technical data
Accuracy 0.5%
0-20 mA, 4-20 mA or 4-20 mA + alarm
< 800 ohm
0.1-30 s adjustable
0-10 kHz, 50% duty cycle
0.1-30 s adjustable
24 V d.c., 30 mA, 1 KΩ ≤ R
load
3-30 V d.c., max. 110 mA, 200 Ω ≤ R
Changeover relay, time constant same as current time constant
42 V a.c./2 A, 24 V d.c./1A
11-30 V d.c., R
= 4.4 KΩ
i
50 ms
I
= 2.5 mA, I
= 7 mA
11 V d.c.
30 V d.c.
Flow rate, 2 totalizers, low flow cut-off, empty pipe cut-off, flow direction, error system, operating time,
uni/bidirectional flow, limit switches, pulse output, control for cleaning unit
All inputs and outputs are galvanically isolated
0-9.9% of maximum flow
1
Detection of empty pipe
)
Two eight-digit counters for forward, net or reverse flow
Background illumination with alphanumerical text, 3 × 20 characters to indicate flow rate, totalized
values, settings and faults
Reverse flow indicated by negative sign
Time constant as current output time constant
Automatic
> 1 x 10
14
Sensor size depending pulsating d.c. current (125 mA)
Display version during operation: −20 to +50°C
Blind version during operation: −20 to +60°C
During storage: −40 to +70°C (RH max. 95%)
PTB
(cold water)
6.221
99.19
Without serial communication
HART
Fibre glass-reinforced polyamide
IP 67 to EN 60529 and DIN 40050 (1 m w.g. for 30 minutes)
18-1000 Hz random, 3.17 G rms in all directions to EN 60068-2-36
Standard 19" insert of aluminium/steel (DIN 41494)
Width: 21 TE
Height: 3 HE
IP 20 to EN 60529 and DIN 40050
Version: 1 G, 1-800 Hz sinusoidal in all directions to EN 60068-2-36
Emission: EN 50081-1 (Light industry)
Immunity: EN 50082-2 (Industry)
115-230 V a.c. +10% to −15%, 50-60 Hz
11-30 V d.c. or 11-24 V a.c.
230 V a.c.: 9 VA
24 V d.c.: 9 W, I
= 380 mA, I
N
ST
12 V d.c.: 11 W, I
= 920 mA, I
N
DKFD.PS.027.W3.02
≤ 10 KΩ, short-circuit-protected
≤ 10 KΩ
load
= 8 A (30 ms)
= 4 A (250 ms)
ST
MAG 5000 and MAG 5000 CT