Commissioning; Keypad And Display Layout - Siemens MAG 1100 Handbook

Electromagnetic flowmeters
Table of Contents

Advertisement

SITRANS F M MAGFLO

8. Commissioning

8.1
Keypad and display
layout
Keypad
Display
56
8. Commissioning
The keypad is used to set the flowmeter. The function of the keys is as follows:
TOP UP KEY
FORWARD KEY
BACKWARD KEY
CHANGE KEY
SELECT KEY
LOCK/UNLOCK KEY
The display is alphanumerical and indicates flow values, flowmeter settings and error messages.
The upper line is for primary flow readings and will always show either flow rate, totalizer 1 or totalizer 2.
The line is divided into 3 fields.
S: Sign field
P: Primary field for numerical value
U: Unit field
The centre line is the title line (T) with individual information according to the selected operator or
setup menu.
The lowest line is the subtitle line (ST) which either will add information to the title line or keep
individual information independent of the title line.
F: The alarm field.
Two flashing triangles will appear by a fault condition.
M: The mode field. The symbols indicate the following.
Communication mode
Service mode
Operator menu
Product identity
Language mode
L: The lock field. Indicates the function of the lock key.
Ready for change
Value locked
DKFD.PS.027.W3.02
This key (hold 2 sec.) is used to switch between operator menu
and setup menu. In the converter setup menu, a short press will
cause a return to the previous menu.
This key is used to step forward through the menus. It is the only
key normally used by the operator.
This key is used to step backward through the menus.
This key changes the settings or numerical values.
This key selects the figures to be changed.
This key allows the operator to change settings and gives access
to submenus.
Basic settings
Output
External input
Sensor characteristics
Reset mode
Access to submenu
RESET MODE: Zero setting of
totalizers and initialization of setting
Operator active
Operator inactive

Hide quick links: