Dc Connection Data; Control Unit (Ccu-24) Connection Data - ABB ACS580-04 Hardware Manual

Drive modules (200 to 500 kw)
Hide thumbs Also See for ACS580-04:
Table of Contents

Advertisement

118 Technical data
Maximum recommended
motor cable length

DC connection data

Control unit (CCU-24) connection data

External power supply
Term. 40, 41
+24 V DC output
(Term. 10)
Digital inputs DI1...DI6
(Term. 13...18)
Relay outputs RO1...RO3
(Term. 19...27)
Analog inputs AI1 and AI2
(Term. 2 and 5)
Analog outputs AO1 and
AO2
(Term. 7 and 8)
Reference voltage output for
analog inputs +10V DC
(Term. 4)
Safe torque off (STO) inputs
IN1 and IN2
(Term. 37 and 38)
Control panel - drive
connection
Vector control
300 m (984 ft)
Note: Motor cable longer than 100 m (328 ft) is allowed but then the EMC
Directive requirements of Category C3 may not be fulfilled.
Drive type
U
= 400 V
N
ACS580-04-505A-4
ACS580-04-585A-4
ACS580-04-650A-4
ACS580-04-725A-4
ACS580-04-820A-4
ACS580-04-880A-4
Maximum power: 36 W, 1.50 A at 24 V AC/DC ±10% as standard
Terminal size: 0.14...2.5 mm
Total load capacity of this outputs is 6.0 W (250 mA / 24 V) minus the power
taken by the option modules installed on the board.
Terminal size: 0.14...2.5 mm
Input type: NPN/PNP
Terminal size: 0.14...2.5 mm
DI1...DI5 (Term.13...17)
12/24 V DC logic levels: "0" < 4 V, "1" > 8 V
R
: 2,68 kohm
in
Hardware filtering: 0.04 ms, digital filtering: 2 ms sampling
DI6 (Term.18)
Can be used as a digital or frequency input.
12/24 V DC logic levels: "0" < 3 V, "1" > 8 V
R
: 6.2 kohm
in
Max. frequency 16 kHz
Symmetrical signal (duty cycle D = 0.50)
250 V AC / 30 V DC, 2 A
Terminal size: 0.14...2.5 mm
Current/voltage input mode is selected with a parameter
Current input: 0(4)...20 mA, R
Voltage input: 0(2)...10 V, R
Terminal size: 0.14...2.5 mm
Inaccuracy: typical ±1%, max. ±1.5% of full scale
Inaccuracy for Pt100 sensors: 10 °C (50 °F)
Current/voltage output mode for AO1 is selected with a parameter.
Current output: 0...20 mA, R
Voltage input: 0...10 V, R
Terminal size: 0.14...2.5 mm
Inaccuracy: ±1% of full scale (in voltage and current modes)
Max. 20 mA output
Inaccuracy: ±1%
24 V DC logic levels: "0" < 5 V, "1" > 13 V
R
: 2.47 kohm
in
Terminal size: 0.14...2.5 mm
EIA-485, male RJ-45 connector, max. cable length 100 m
Scalar control
300 m (984 ft)
I
(A)
DC
640
714
870
909
1033
1120
2
2
2
2
: 100 ohm
in
: > 200 kohm
in
2
: < 500 ohm
load
: > 100 kohm (AO1 only)
load
2
2
Capacitance (mF)
14
14
14
21
21
21

Advertisement

Table of Contents
loading