System Control & Maintenance - CYBEX autoview 200 Installer And User Manual

Hide thumbs Also See for autoview 200:
Table of Contents

Advertisement

AutoView 200 Installer/User Guide
System Control &
Maintenance
The following commands are used for system control and maintenance.
Enter the command sequences to perform the actions described in the
table below.
Key Sequence
Action
<CM>Kn<Enter>
Sets the keyboard scan set where n is a scan set number 1-3.
<CM>MR<Enter>
If you hot-plug your mouse cable, you may experience a loss of
mouse signal. Use this command to restore the signal if you are
using a PC with a standard PS/2 mouse driver.
<CM>MW<Enter>
If you hot-plug your mouse cable, you may experience a loss of mouse
signal. Use this command to restore the signal if you are using a PC
with a Microsoft IntelliMouse or other wheel mouse driver.
<CM>AV<Enter>
Displays the current firmware version of your AutoView 200.
<CM>SG<Enter>
Enables the scan Go command (By address only)
<CM>SH<Enter>
Enables the scan Halt command
<CM>M+<Enter>
Enables mouse suspension of scanning
<CM>M-<Enter>
Disables mouse suspension of scanning
<CM>H1<Enter>
Changes the hot-key sequence to the default: (NumLock, -)
<CM>H2<Enter>
Changes the hot-key sequence to the 1st alternate: (NumLock, *)
<CM>H3<Enter>
Changes the hot-key sequence to the 2nd alternate: (CTRL, ~)
<CM>OSD0<Enter>
Disables the OSD Sequence
<CM>OSD1<Enter>
Changes the OSD sequence to the default: (CTRL, CTRL)
<CM>OSD2<Enter>
Changes the OSD sequence to the 1st alternate: (Alt, Alt)
<CM>OSD3<Enter>
Changes the OSD sequence to the 2nd alternate: (Shift, Shift)
<CM>
<CM>
<Enter>
<Enter>
<CM>
<CM>
<CM>ZM<Enter>
<Enter>
<Enter>
Use this command to resynchronize the mouse after a device or
computer hot-plug. Repeat, if necessary, until synchronization is
re-established.
Note: Using this command while the mouse is operating
correctly will cause the mouse to lose sync.
14

Hide quick links:

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the autoview 200 and is the answer not in the manual?

Table of Contents