Appendices
Configure your terminal program to the following settings:
38,400 Baud
8 Bits
No Parity
1 Stop Bit
No Flow Control
Activate the OSD menu on your AutoView 200 by tapping the Control key
twice. Enter Control twice more to activate the Administrator Commands
screen and then select Administrator Functions.
Use the down arrow key to highlight the menu selection for FLASH Upgrade,
then hit Enter.
A menu screen will appear and ask if you wish to continue. You must type
out the word Yes before preceding. Once you have done this, the AutoView
will go into a standby mode and wait for data from the PC. (Note: The
keyboard, video and mouse are disabled during the FLASH upgrade.)
The final step is to send the FLASH file from your terminal program. To do
this, you will need to use the transfer function from whichever program
you are using. Send the FLASH file as a text file. The transfer should be
completed within five minutes.
The AutoView 200 will automatically check the upgrade and make sure
that it is valid. If the AutoView detects an error it will abort the upgrade
and retain the original OSD firmware. Otherwise, it will return the message
"Flash Upgrade Successful". If the file read does not validate, you will be
prompted to re-transfer your file.
33