Vega VEGAFLEX 61 Operating Instructions Manual page 47

Level sensor
Hide thumbs Also See for VEGAFLEX 61:
Table of Contents

Advertisement

Fig. 23: Measuring ranges of VEGAFLEX 61
1
Reference plane
2
Probe length L
3
Measuring range (default setting refers to the measuring range in water)
4
Upper dead band (see diagrams under Accuracy - grey section)
5
Lower dead band (see diagrams under Accuracy - grey section)
Output variable
Output signal
Cycle time
Sensor address
Current value
Damping (63 % of the input variable)
Fulfilled NAMUR recommendations
Resolution, digital
Accuracy (similar to DIN EN 60770-1)
Process reference conditions according to DIN EN 61298-1
Temperature
-
Relative humidity
-
Air pressure
-
VEGAFLEX 61 • Profibus PA
4
2
3
5
1
2
digital output signal, format according to IEEE-754
min. 1 s (dependent on the parameter setting)
126 (default setting)
10 mA, ±0.5 mA
0 ... 999 s, adjustable
NE 43
> 1 mm (0.039 in)
+18 ... +30 °C (+64 ... +86 °F)
45 ... 75 %
+860 ... +1060 mbar/+86 ... +106 kPa
(+12.5 ... +15.4 psig)
10 Supplement
1
4
3
5
47