Specifications; General Specifications; Plc Cpu Specifications - Omron SYSMAC CS1 Operation Manual

Hide thumbs Also See for SYSMAC CS1:
Table of Contents

Advertisement

Specifications

1-11 Specifications

1-11-1 General Specifications

Item
Power supply voltage
Power consumption
Vibration resistance
Shock resistance
Ambient temperature
Humidity
Atmosphere
Weight
Dimensions

1-11-2 PLC CPU Specifications

Common Specifications
Item
Control method
I/O control method
Programming
CPU processing mode
Instruction length
Ladder instructions
Execution time
Execution time
Overhead processing time
Number of Expansion Racks
Number of tasks
20
4.875 to 5.25 VDC
CS1PC-PCI01-DRM SYSMAC CS1 Board:
CS1PC-PCI01H-DRM SYSMAC CS1 Board:
CS1PC-EIC01 Expansion I/O Board:
Conforms to JIS C0911:
10 to 57 Hz; 0.075 mm amplitude
2
57 to 150 Hz; 9.8 m/s
acceleration in X, Y, and Z directions, for 80 minutes each
Conforms to JIS C0912: 147 m/s
Operating: 0° to 55°C
Storage:
–20° to 75°C (excluding battery)
10% to 90% (without condensation)
Must be free of corrosive gases.
CS1PC-PCI01-DRM,
CS1PC-PCI01H-DRM SYSMAC CS1 Board:
CS1PC-EIC01 Expansion I/O Board:
CS1PC-PCI01-DRM,
CS1PC-PCI01H-DRM SYSMAC CS1 Board:
(The depth measurement is the measurement at the battery.)
Expansion I/O Board Expansion I/O Board:
(The depth measurement is the measurement of the Board components.)
Stored program
Cyclic scan and immediate processing are both possible.
Ladder diagram
CS1PC-PCI01-DRM: Normal Mode, Parallel Processing Mode with
Asynchronous Memory Access, Parallel Processing Mode with
Synchronous Memory Access, or Peripheral Servicing Priority Mode
CS1PC-PCI01H-DRM: Normal Mode or Peripheral Servicing Priority
Mode
1 to 7 steps per instruction
Approx. 400 (3-digit function codes)
CS1PC-PCI01-DRM:
CS1PC PCI01 DRM:
CS1PC-PCI01H-DRM:
CS1PC-PCI01-DRM:
Normal mode:
Parallel processing: 0.2 ms min.
CS1PC-PCI01H-DRM:
7 max. (C200H Expansion I/O Racks: 3 max.)
288 (cyclic tasks: 32, interrupt tasks: 256)
When using CS1PC-PCI01H-DRM, interrupt tasks can be executed
every cycle (called additional tasks) in the same way as cyclic tasks.
As a result, the maximum number of cyclic tasks is actually 288.
Note Cyclic tasks are executed each cycle and are controlled with
TKON(820) and TKOF(821) instructions.
Note The following 4 types of interrupt tasks are supported.
Power OFF interrupt tasks:1 max.
Scheduled interrupt tasks: 2 max.
I/O interrupt tasks:
External interrupt tasks:
Specifications
1.7 A max.
1.3 A max.
0.1 A max.
2
in X, Y, and Z directions, 3 times each
300 g max.
100 g max.
106.7 × 176.6 × 18.7 mm (W × H × D)
106.7 × 105.5 × 11 mm (W × H × D)
Specification
0.04 µs min.
0.04 µs min.
0.08 µs min.
0.3 ms min.
0.5 ms min.
32 max.
256 max.
Section
1-11
Reference
---
---
---
---
---
---
---
---
---
---

Advertisement

Table of Contents
loading