Other Installation Considerations; Environmental Requirements; Environmental Requirements For The Press - Xerox Versant 80 Press Installation Manual

Xerox versant 80 press with xerox freeflow print server
Hide thumbs Also See for Versant 80 Press:
Table of Contents

Advertisement

Other Installation Considerations

Other Installation Considerations for the Press
Physical delivery of the press and print server will be by a Xerox authorized Carrier. The carrier will install and perform a
functional check of the press. The carrier will review the software/documentation with the customer. For the press the
customer is responsible for connecting and configuring the equipment on their network.
There should be a minimum of 78 inches (1981 mm) clearance from the floor to the nearest overhead obstruction.
Other Installation Considerations for the Print Servers
One network drop is required for installation of the print server.
The customer is responsible for configuring the print server to the network.
To enable system administrators and others to work at the print server, the work surface should be desk height.
To enable the Xerox service representative to safely repair the system, the work surface should measure at least 41
in(1041.4 mm) to 30 in(762 mm).
The work surface of the print server must not impede on the space required by the machine and any attached accessories
unless the work surface is a table that has wheels and can be easily moved.
A secure but accessible place near the print server must be established in which to store the print server media and software.
Xerox personnel may not be able to provide services unless these materials are available.
The communications cables, which connect the print server to the press, vary in length; refer to Module Dimensions section
of this guide.
NOTE:
If the available floor space is an issue, the print server components may be placed on the right side of the press.
CAUTION:
Avoid placing the print server directly behind the press. Heat generated by the press may cause the print server to
overheat and stop functioning properly.

Environmental Requirements

Environmental Requirements for the Press

Item
Minimum
50° F/10° C
Temperature
15%
Relative
Humidity (RH)
Approximately
4778
Heat emission
BTU/Hour (Standby)
Power
1.4 KW
consumption
(Standby)
Noise
40.8 dBA
(Standby)
Altitude
0 feet/0 meters
Customer Expectation & Installation Guide
Maximum
90° F/32° C
NOTE: Temperatures above 90° F (32°
C) require reduced relative humidity to
maintain the specific/optimal
performance.
85%
Approximately 18,772 BTU/Hour
(Running)
5.5 KW (Running)
65 dBA (Running)
8,200 feet/2,500 meters
NOTE: Altitudes above 2,000 feet
(609.9 meters) may require field
adjustment and may degrade
performance.
Recommended
68-76° F/20-24° C
NOTE: Better performance is achieved when
environmental conditions are maintained at
these temperatures.
45%
6,561.68 feet/2,000
meters
Versant 80 Press