Electrical Requirements
All machine optional accessories and print servers should be placed within 6 feet (3 meters) of wall outlets. Ensure that there are enough wall
outlets available for optional accessories and the print server.
Press Electrical Requirements
Electrical requirements must be satisfied prior to equipment delivery. The Press requires a dedicated 20 Amp service.
Item
Nominal Voltage
Amperage circuit
Current rating
Cycles
Frequency (Hz)
In rush current
Power consumption
Power Cord Length
Plug/Receptacle Diagram
Electrical Requirements for Optional Devices
NOTE:
HCF, BR Finisher, and BR Booklet Finisher plug directly into press and require no additional power receptacle.
NOTE:
Use surge protection only as required and is the responsibility of the customer.
International Requirements
Each optional feeding and finishing device requires an additional 100-240 VAC or 208-240 VAC country-specific power
receptacles.
USA Requirements
Each optional feeding and finishing device requires one additional NEMA 5-15R or 5-20R receptacle; refer to the following
diagram and table.
Customer Expectation & Installation Guide
Main processor
North America (NA): 208-240 VAC (XC) -10%/+6%
Europe: 220-240 VAC (XE) ±10%
20*
*Requires a 20 circuit and receptacle
16
50/60 Hz Single Phase
NA: 50/60 ±3%
Europe: 50 ±3%
100A or less
NA: 208V, 3.66KW or less
NA: 240V, 4.224KW or less
Europe: 220V, 4.4KW or less
Europe: 240V, 4.8KW or less
10 feet/3 meters
North America Plug: NEMA 6-20P
North America Receptacle: NEMA 6-20R
A single power cord (USA plug and receptacle diagram shown above) is required for the press.
Europe: PCE Shark 023-6 Plug
Europe: receptacle that mates to the PCE Shark 023-6 plug
Versant 80 Press