Global Reset Input (Optional)

The global reset input (POWER_INHIBIT) is provided to force all outputs to be switched off.
connected to GND
floating
DSUB25 female

Table 4: Global Reset Connector Pin Assignment

The signals shall be connected by an isolated contact (e.g. relays), and must not be connected to
other potentials.
The input has an internal 10 kΩ pull-up resistor to 5V and an input impedance of 10 kΩ.
It is possible to invert the logic of this signal by changing a jumper switch inside of the power box..
Jumper at Pin
1 – 2
2 – 3
28. May 2013
Power outputs disabled
Power outputs may be enabled by the remote control
Pin Signal
1
NC
14
NC
2
NC
15
NC
3
NC
16
NC
4
NC
17
NC
5
NC
18
NC
6
NC
19
NC
7
NC
20
NC
8
NC
21
NC
9
NC
22
NC
10
NC
23
NC
11
NC
24
NC
12
NC
25
GND
13
POWER_INHIBIT
POWER_INHIBIT Input
open
connected to GND
open
connected to GND
Comment
reserved
reserved
reserved
reserved
reserved
reserved
reserved
reserved
reserved
reserved
reserved
reserved
reserved
reserved
reserved
reserved
reserved
reserved
reserved
reserved
reserved
reserved
reserved
Ground of the aux. supply, connected to USB ground
Inhibit input
Functionality
power disabled (INTERLOCK)
power enabled
power enabled
power disabled (RESET)