Read Power Supply Data From File Dialog; Output Configuration Dialog - Wiener PL512 Technical Manual

Modular power supply system
Hide thumbs Also See for PL512:
Table of Contents

Advertisement

Select the next existing channel for the other dialogs. The current channel is displayed at the
title bar.
DVM
Opens a large window showing the measurement data of one channel.
OutputConfiguration
Opens the Output Configuration Dialog.
OutputCalibration
This dialog is reserved for service personal.
System » Configuration
Opens the Global and Network Configuration Dialog.
System » Firmware Update
Allows to update the firmware of the main processor.
Stop
Start
Allow to interrupt and resume the communication with the PL512/PL506.
Help » Info
Here you have access to the version number of the software.

3.3.1 Read Power Supply Data From File Dialog

This dialog can be used to copy a XML configuration file from disk to the PL512/PL506.
It is possible to copy
each configuration file
channel
to
corresponding power
supply channel (e.g.
U0 → U0, U1 →
U1, ...) or to copy one
configuration
channel to multiple
power
supply
channels.

3.3.2 Output Configuration Dialog

This dialog allows the detailed configuration of each power supply channel.
The Measurement group shows the measured sense voltage, terminal voltage and current. The sense
voltage is the voltage at the sense lines, which are connected to the load. Terminal voltage means the
voltage at the terminals of the PL512/PL506.
Depending on the used modules, an analog or digital value of the most critical point of the power
module is displayed.
The power of the load and the output power of the module are calculated values.
28. May 2013