Textual Convention: DisplayString
|
|
|
Size: 1..4
|
|
+-- -RW- INTEGER
|
|
|
Range: 0..127
|
|
+-- -R-- BitString outputStatus(4)
|
|
|
Values: outputOn(0), outputInhibit(1),
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
+-- -R-- Opaque
|
|
|
Textual Convention: Float
|
|
|
Size: 7
|
|
+-- -R-- Opaque
|
|
|
Textual Convention: Float
|
|
|
Size: 7
|
|
+-- -R-- Opaque
|
|
|
Textual Convention: Float
|
|
|
Size: 7
|
|
+-- -R-- EnumVal
|
|
|
Values: OK(-128), FAILURE(127)
|
|
+-- -RW- EnumVal
|
|
|
Values: OFF(0), ON(1)
|
|
+-- -RW- Opaque
|
|
|
Textual Convention: Float
|
|
|
Size: 7
|
|
+-- -RW- INTEGER
|
|
|
Range: -128..127
|
|
+-- -RW- Opaque
|
|
|
Textual Convention: Float
|
|
|
Size: 7
|
|
+-- -RW- INTEGER
|
|
|
Range: 0..65535
|
|
+-- -RW- Opaque
|
|
|
Textual Convention: Float
|
|
|
Size: 7
|
|
+-- -RW- Opaque
|
|
|
Textual Convention: Float
|
|
|
Size: 7
|
|
+-- -RW- Opaque
|
|
|
Textual Convention: Float
|
|
|
Size: 7
|
|
+-- -RW- Opaque
|
|
|
Textual Convention: Float
|
|
|
Size: 7
|
|
+-- -RW- Opaque
|
|
|
Textual Convention: Float
|
|
|
Size: 7
|
|
+-- -RW- Opaque
|
|
|
Textual Convention: Float
|
|
|
Size: 7
|
|
+-- -RW- Opaque
|
|
|
Textual Convention: Float
|
|
|
Size: 7
|
|
+-- -RW- Opaque
|
|
Textual Convention: Float
|
|
Size: 7
|
|
|
+-- -R-- INTEGER
|
|
Range: 1..255
|
|
|
+--groupsTable(4)
|
|
|
+--groupsEntry(1)
|
|
Index: groupsIndex
|
|
|
+-- ---- EnumVal
|
|
Values: ALL(0)
|
+-- --W- EnumVal
|
Values: UNDEFINED(-1), OFF(0), ON(1)
|
+--communication(5)
|
|
|
+--snmp(1)
|
|
|
+--snmpCommunityTable(1)
28. May 2013
outputGroup(3)
outputFailureMinSenseVoltage(2),
outputFailureMaxSenseVoltage(3),
outputFailureMaxTerminalVoltage(4),
outputFailureMaxCurrent(5),
outputFailureMaxTemperature(6),
outputFailureMaxPower(7),
outputFailureTimeout(9),
outputCurrentLimited(10), outputRampUp(11),
outputRampDown(12)
outputMeasurementSenseVoltage(5)
outputMeasurementTerminalVoltage(6)
outputMeasurementCurrent(7)
outputMeasurementTemperature(8)
outputSwitch(9)
outputVoltage(10)
outputAdjustVoltage(11)
outputCurrent(12)
outputSupervisionBehavior(15)
outputSupervisionMinSenseVoltage(16)
outputSupervisionMaxSenseVoltage(17)
outputSupervisionMaxTerminalVoltage(18)
outputSupervisionMaxCurrent(19)
outputConfigMaxSenseVoltage(21)
outputConfigMaxTerminalVoltage(22)
outputConfigMaxCurrent(23)
outputSupervisionMaxPower(24)
groupsNumber(3)
groupsIndex(1)
groupsSwitch(9)