Wiener PL512 Technical Manual

Modular
Hide thumbs Also See for PL512:

Advertisement

Quick Links

PL512
Modular Power Supply System
Technical Manual
8. June 2010
1
*00679.A1

Advertisement

Table of Contents
loading

Summary of Contents for Wiener PL512

  • Page 1 PL512 Modular Power Supply System Technical Manual 8. June 2010 *00679.A1...
  • Page 2: General Remarks

    Discharge the primary DC filter-capacitors by use of a well insulated 22 ohm 10W resistor. We recommend in case of any malfunction to send the power box to Wiener or to one of our representative for service 20. June 2006 *00679.A1...
  • Page 3: Declaration Of Conformity

    Declaration of Conformity Low Voltage Directive 73/23/EEC and EMC Directive Art. 10.1 of 89/336/EEC Plein & Baus GmbH declare under our own responsibility that the product PL5 / PL6, F8-12 Items: 0P00.xxxx; 0P01.xxxx; 0P04.xxxx; 0M11.xxxx; 0M21.xxxx is in accordance with the following standards or standardized documents: EN 60 950-1:2001 Niederspannungsrichtlinie [low voltage + Corr:2004-09...
  • Page 4: Table Of Contents

    2.9.1 LED Description....................7 2.9.2 Function of the Switches..................7 2.9.3 Main Operating Modes and Associated Submenus..........8 2.10 Power Output and Sense Connections..............9 3 PL512 Control and Setup via USB..................10 3.1 Installation........................10 3.2 The Main Window....................11 3.3 Description of the Menu Items................12 3.3.1 Read Power Supply Data From File Dialog............13...
  • Page 5 Figures Figure 2.1: PL512 Front Side with Interlock and Water-Cooled Option......2 Figure 2.2: PL512 Front Side with Display Option.............2 Figure 2.3: PL512 Rear Side (Power Output Connections)........8 Figure 7.1: MARA Power Bin...................16 Figure 7.2: Current Bar Dimensions................24 Figure 7.3: Two Channels Parallel................25 Figure 7.4: Three Channels Parallel................25...
  • Page 6: General Information

    1 General Information Features up to 12 independent processor controlled, potential free outputs ● up to 3 kW DC output power ● Programmable output voltage, current limit and rise/fall time ● Measurement of output voltages and current ● Fully controlled, programmable trip thresholds (min./max. sense voltage, max ●...
  • Page 7: Pl512 Power Box

    2 PL512 Power Box The PL512 front appearance differs slightly, depending on the existing options. Figure 2.1: PL512 Front Side with Interlock and Water-Cooled Option Figure 2.2: PL512 Front Side with Display Option AC Mains Connection The AC input connections are made with the Hirschmann connector series ST.
  • Page 8: Main Switch

    Main Switch The green illuminated rocker switch works as a global inhibit input. Power outputs disabled ● Switch is lighting, power outputs may be enabled by the remote control. ● This switch is a logic switch only. It does not disconnect the mains supply. With the Alphanumeric Display Option the switch is omitted.
  • Page 9: Global Reset Input (Optional)

    Global Reset Input (Optional) The global reset input (POWER_INHIBIT) is provided to force all outputs to be switched off. connected to GND Power outputs disabled ● floating Power outputs may be enabled by the remote control ● DSUB25 female Pin Signal Comment reserved reserved...
  • Page 10: Channel-Wise Interlock Input (Optional)

    Channel-Wise Interlock Input (Optional) The channel-wise interlock inputs are provided to force a dedicated output to be switched off. DSUB25 female Pin Signal Comment Interlock U0 + Interlock U0 - Interlock U1 + Interlock U1 - Interlock U2 + Interlock U2 - Interlock U3 + Interlock U3 - Interlock U4 +...
  • Page 11: Global Stop And Start Inputs (Optional)

    Global Stop and Start Inputs (Optional) This inputs allow to switch off the outputs channels (emergency stop) or to switch on all power supply outputs (e.g. used for maintenance) . DSUB25 female Pin Signal Comment reserved reserved reserved reserved reserved reserved reserved reserved...
  • Page 12: Alphanumeric Display (Optional)

    ● 2.9.2 Function of the Switches After the PL512 has been switched on by pushing the “Power” switch up, the main operation modes can be selected by pushing the “Mode Select” switch up or down. Many main operating modes do have one or more submenus, which can be accessed by a special procedure.
  • Page 13: Main Operating Modes And Associated Submenus

    The following example describes the detailed steps to enter a sub menu and change the IP gateway address. Description Switch Display switch the crate on P▲ 5.01V 1.2A select the requested main M▲ or M▼ (until right mode is TCPIP: no link operation mode displayed) enter submenu...
  • Page 14: Power Output And Sense Connections

    Change the TCP/IP port of the web server HTTP Port Change the TCP/IP port of the SNMP server SNMP Port Restore the default SNMP settings (community SNMP Default strings) 2.10 Power Output and Sense Connections Figure 2.3: PL512 Rear Side (Power Output Connections) 8. June 2010 *00679.A1...
  • Page 15: Pl512 Control And Setup Via Usb

    The low voltage DC output at the rear side of the power supply is provided by 4 mm sockets (Figure 2.3: PL512 Rear Side). The channels are arranged from left to right starting with U0. Positive output is up and negative output is down.
  • Page 16: The Main Window

    Now connect the PL512 with your mains supply and use an USB cable to connect the computer with the PL512. The computer will detect the new connected hardware and ask to connect to Windows Update.
  • Page 17: Description Of The Menu Items

    Switch » Group 2 On ● Switch » Group 2 Off ● This are commands to demonstrate the grouping functions of the PL512. The default factory setting is group 1 for channels 0..5 and group 2 for channels 6..11. SelectOutput ●...
  • Page 18: Read Power Supply Data From File Dialog

    The sense voltage is the voltage at the sense lines, which are connected to the load. Terminal voltage means the voltage at the terminals of the PL512. Depending on the used modules, an analog or digital value of the most critical point of the power module is displayed.
  • Page 19: Global And Network Configuration Dialog

    In this situations the advanced (PID) regulator of the Moderate Regulation should be used. If the load is connected with really long or high-inductance cable, the Slow Regulation check box should be checked additionally. This increases the time constant of the I-Regulator. The Control and Status group has buttons to switch the channel on or off.
  • Page 20: Web Server

    4 Web Server The PL512 has a built-in web-server which allows the monitoring of the power supply with a standard web browser. 5 SNMP Control The SNMP (Simple Network Management Protocol) is generally used to monitor and control computers and network routers.
  • Page 21 commissioning support due to automatic scanning of the network and registration of ● communication stations restricting access rights by the underlying Microsoft DCOM. ● The details of the OPC server can be found in the manual delivered with the OPC server software.
  • Page 22: The Mara Power Bin

    7 The MARA Power Bin For easy exchange of the PL512 Power Box the special bin (MARA) is provided: The low voltage/high current cabling is connected to M5 threaded bolts (MULTICONTACT). The arrangement is the same as at the power box: Starting from left with U0, and positive outputs up –...
  • Page 23: Appendix A: Data Sheet

    Appendix A: Data Sheet Rated Input Voltage: 106 – 230 V AC, +/- 15% variation allowed Rated Input Current: 16 A Sinusoidal: EN 60555, IEC 555 pow. fact. 0,98 (230VAC) 50/60 Hz Inrush current: 16 A, cold unit Output Insulation (SELV) CE EN 60950 , ISO 380, VDE 0805, UL 1950, C22.2.950 DC Output power with different input voltages at the rated current (16A), calculated with typical efficiency of 75%...
  • Page 24 1%: < 33 ms DC Output Characteristics: Sense compensation Limited to < 10V or nominal voltage (whichever is lower). range: Regulation mode: The voltage at the sense connection point is regulated. Floating range: 500 V test voltage Noise and ripple: Voltage <...
  • Page 25 Communication Ethernet 10/100M, USB 2 Measurement Accuracy (typical values) Voltage ± 0.1% of the maximum output voltage of the channel Current MDC (single module) ± 1% MDC (paralleled) ± 1% ± 1 % Construction max. 6 modules, up to 3 kW / 3,6kW 3 U box with extraction features, output power...
  • Page 26: Appendix B: Ordering Information

    Appendix B: Ordering Information 0P11 Standard .xxxx 0M11 Special versions for CERN .xxxx The left side of the ordering number is not descriptive, it is randomly assigned to the requested module & options configuration. Up to six power modules may be used inside of one power box.
  • Page 27: Appendix C: Snmp Oid Tree

    Range: 0..127 This is the tree view of the wiener-specific SNMP namespace. It could be generated with the command „snmptranslate -w 80 -Tp WIENER-CRATE-MIB::wiener“. Because it's a general definition, usable for different types of crates, some items may be not implemented in the real hardware.
  • Page 28 Textual Convention: DisplayString Size: 1..4 +-- -RW- INTEGER outputGroup(3) Range: 0..127 +-- -R-- BitString outputStatus(4) Values: outputOn(0), outputInhibit(1), outputFailureMinSenseVoltage(2), outputFailureMaxSenseVoltage(3), outputFailureMaxTerminalVoltage(4), outputFailureMaxCurrent(5), outputFailureMaxTemperature(6), outputFailureMaxPower(7), outputFailureTimeout(9), outputCurrentLimited(10), outputRampUp(11), outputRampDown(12) +-- -R-- Opaque outputMeasurementSenseVoltage(5) Textual Convention: Float Size: 7 +-- -R-- Opaque outputMeasurementTerminalVoltage(6) Textual Convention: Float Size: 7...
  • Page 29 +--snmpCommunityEntry(1) Index: snmpAccessRight +-- ---- EnumVal snmpAccessRight(1) Values: public(1), private(2), admin(3), guru(4) +-- -RW- String snmpCommunityName(2) Size: 0..14 +-- -RW- INTEGER snmpPort(2) +--powersupply(6) +-- -R-- String psSerialNumber(2) Textual Convention: DisplayString Size: 0..255 +-- -R-- INTEGER psOperatingTime(3) +-- -RW- String psDirectAccess(1024) Size: 1..14 8.
  • Page 30: Appendix D: Parallel Connection Of Output Channels

    Appendix D: Parallel Connection of Output Channels A set of six current bars ( 4-fold ) will be delivered by each power bin in a companion-assembly-pack. How to use the current bars If the power supply has channels with more than one contact pair, use the current bars to connect each option.
  • Page 31 8. June 2010 *00679.A1...
  • Page 32: Figure 7.3: Two Channels Parallel

    Figure 7.3: Two Channels Parallel Figure 7.4: Three Channels Parallel Figure 7.5: Four Channels Parallel 8. June 2010 *00679.A1...

Table of Contents