Wiener PL512 Technical Manual page 28

Modular power supply system
Hide thumbs Also See for PL512:
Table of Contents

Advertisement

WIENER-CRATE-MIB::sysStatus.0 = BITS: 00
WIENER-CRATE-MIB::sysHardwareReset.0 = INTEGER: 0
WIENER-CRATE-MIB::outputNumber.0 = INTEGER: 6
WIENER-CRATE-MIB::outputIndex.u0 = INTEGER: u0(1)
WIENER-CRATE-MIB::outputIndex.u1 = INTEGER: u1(2)
WIENER-CRATE-MIB::outputIndex.u2 = INTEGER: u2(3)
WIENER-CRATE-MIB::outputIndex.u3 = INTEGER: u3(4)
WIENER-CRATE-MIB::outputIndex.u4 = INTEGER: u4(5)
WIENER-CRATE-MIB::outputIndex.u5 = INTEGER: u5(6)
WIENER-CRATE-MIB::outputName.u0 = STRING: U0
WIENER-CRATE-MIB::outputName.u1 = STRING: U1
WIENER-CRATE-MIB::outputName.u2 = STRING: U2
WIENER-CRATE-MIB::outputName.u3 = STRING: U3
WIENER-CRATE-MIB::outputName.u4 = STRING: U4
WIENER-CRATE-MIB::outputName.u5 = STRING: U5
WIENER-CRATE-MIB::outputGroup.u0 = INTEGER: 1
WIENER-CRATE-MIB::outputGroup.u1 = INTEGER: 2
WIENER-CRATE-MIB::outputGroup.u2 = INTEGER: 1
WIENER-CRATE-MIB::outputGroup.u3 = INTEGER: 2
WIENER-CRATE-MIB::outputGroup.u4 = INTEGER: 1
WIENER-CRATE-MIB::outputGroup.u5 = INTEGER: 2
WIENER-CRATE-MIB::outputStatus.u0 = BITS: 40 outputInhibit(1)
WIENER-CRATE-MIB::outputStatus.u1 = BITS: 40 outputInhibit(1)
WIENER-CRATE-MIB::outputStatus.u2 = BITS: 40 outputInhibit(1)
WIENER-CRATE-MIB::outputStatus.u3 = BITS: 40 outputInhibit(1)
WIENER-CRATE-MIB::outputStatus.u4 = BITS: 40 outputInhibit(1)
WIENER-CRATE-MIB::outputStatus.u5 = BITS: 40 outputInhibit(1)
WIENER-CRATE-MIB::outputMeasurementSenseVoltage.u0 = Opaque: Float: 0.000000 V
WIENER-CRATE-MIB::outputMeasurementSenseVoltage.u1 = Opaque: Float: 0.000000 V
WIENER-CRATE-MIB::outputMeasurementSenseVoltage.u2 = Opaque: Float: 0.000000 V
WIENER-CRATE-MIB::outputMeasurementSenseVoltage.u3 = Opaque: Float: 0.000000 V
WIENER-CRATE-MIB::outputMeasurementSenseVoltage.u4 = Opaque: Float: 0.000000 V
WIENER-CRATE-MIB::outputMeasurementSenseVoltage.u5 = Opaque: Float: 0.000000 V
WIENER-CRATE-MIB::outputMeasurementTerminalVoltage.u0 = Opaque: Float: 0.000000V
WIENER-CRATE-MIB::outputMeasurementTerminalVoltage.u1 = Opaque: Float: 0.000000V
WIENER-CRATE-MIB::outputMeasurementTerminalVoltage.u2 = Opaque: Float: 0.000000V
WIENER-CRATE-MIB::outputMeasurementTerminalVoltage.u3 = Opaque: Float: 0.000000V
WIENER-CRATE-MIB::outputMeasurementTerminalVoltage.u4 = Opaque: Float: 0.000000V
WIENER-CRATE-MIB::outputMeasurementTerminalVoltage.u5 = Opaque: Float: 0.000000V
WIENER-CRATE-MIB::outputMeasurementCurrent.u0 = Opaque: Float: 0.000000 A
WIENER-CRATE-MIB::outputMeasurementCurrent.u1 = Opaque: Float: 0.000000 A
WIENER-CRATE-MIB::outputMeasurementCurrent.u2 = Opaque: Float: 0.000000 A
WIENER-CRATE-MIB::outputMeasurementCurrent.u3 = Opaque: Float: 0.000000 A
WIENER-CRATE-MIB::outputMeasurementCurrent.u4 = Opaque: Float: 0.000000 A
WIENER-CRATE-MIB::outputMeasurementCurrent.u5 = Opaque: Float: 0.000000 A
WIENER-CRATE-MIB::outputMeasurementTemperature.u0 = INTEGER: 24
WIENER-CRATE-MIB::outputMeasurementTemperature.u1 = INTEGER: 25
WIENER-CRATE-MIB::outputMeasurementTemperature.u2 = INTEGER: 24
WIENER-CRATE-MIB::outputMeasurementTemperature.u3 = INTEGER: 26
WIENER-CRATE-MIB::outputMeasurementTemperature.u4 = INTEGER: 25
WIENER-CRATE-MIB::outputMeasurementTemperature.u5 = INTEGER: 29
WIENER-CRATE-MIB::outputSwitch.u0 = INTEGER: off(0)
WIENER-CRATE-MIB::outputSwitch.u1 = INTEGER: off(0)
WIENER-CRATE-MIB::outputSwitch.u2 = INTEGER: off(0)
WIENER-CRATE-MIB::outputSwitch.u3 = INTEGER: off(0)
WIENER-CRATE-MIB::outputSwitch.u4 = INTEGER: off(0)
WIENER-CRATE-MIB::outputSwitch.u5 = INTEGER: off(0)
WIENER-CRATE-MIB::outputVoltage.u0 = Opaque: Float: 3.299805 V
28. May 2013
23
*00679.A4

Hide quick links:

Advertisement

Table of Contents
loading

Related Products for Wiener PL512

This manual is also suitable for:

Pl506

Table of Contents