Use the plug-able sense connector for
sense wiring. The PL-506 has only 4
sense connections per terminal block
whereas the PL-512 has 8.
Fig 4.4: PL-506, sense connector for U0 and U1
4.3

Load Connections

Looking from the rear of the PS, the load connections are as follows: from left to right U0, U1, U2,
U3 and so on. Fig.4.5- shows load and sense connections for U0. Use remote sense for load lines
greater than 1m.
Fig. 4.5: PL-506- external sense
Use internal sense for testing and setup only! Once your load and load lines are setup, then connect
sense lines for the most accurate control of load voltage and current.
28. May 2013
17