Safety Thermostat With Manual Reset - Jolly Mec I-DEA IDRO Installation, Use And Maintenance Manual

Pellet fired stove with boiler
Table of Contents

Advertisement

08.4

SAFETY THERMOSTAT WITH MANUAL RESET

Two safety thermostats are installed on the appliance to read pellet hopper and circulating water temperature respectively and trigger
the shutdown of the appliance when the temperature in the vicinity of the respective probes detect values above the limits set for safety
devices.
The safety thermostats can shutdown the appliance when, for example, the pellet hopper overheats, triggering the pellet thermostat, or
when there is no water circulation in the stove, triggering the water temperature thermostat.
To restore normal appliance operations following forced shutdown by a thermostat, proceed as follows:
F
. 1
ig
C
B
A
TERMOSTATO
TERMOSTATO
ACQUA
I
38
A
B
PELLET
F
G
1. Wait until the appliance is completely cold (on average 20
minutes);
2. Unscrew the thermostat reset button lid on the right side
of the device, below the side panel (see F
A or B)
3. Press the button (A or B) until you hear a CLICK;
4. Refit the hood;
5. Reset the alarm from the device on board display by
H
pressing Button 3 and waiting for the OFF message;
6. Start up again the appliance.
If the alarm persists, contact the Technical Assistance Centre
D
(CAT).
PELLET thermostat, to reset alarm AL07 SAFETY THERMOST
E
WATER thermostat, to reset alarm AL19 THERMIC WATER
Socket unit (F
. 1):
ig
A. Water safety thermostat with manual reset
B. Pellet safety thermostat with manual reset
C. Thermal hydrometer
D. Probe input and actuator output terminal boards
E. 2-way connector for use with external ambient probe where installed
F. Board/PC programming connector
G. Main electrical socket with bipolar switch
H. Room temperature probe
I. Motherboard support
. 1, positions
ig

Advertisement